753 results
Honeywell / Searchpoint Optima Plus
This module can function with input voltages ranging from 22-27V AC or 29-38V DC and provides relay outputs through 4 DPDT relays rated for 5A at 30 VDC or 250 VAC. It supports analog output on four channels at 4–20 mA, corresponding to individual sensors, and connects via RS-485 Modbus communicatio
Honeywell / Sensepoint XCD
The SPXCDULNO1M operates with a voltage range of 16-32 VDC and is rated IP66 for dust and water resistance. This detector can monitor oxygen levels from 0-25% volume, utilizing electrochemical sensing technology (Surecell). It includes three relays for alarm and fault signals, and provides output si
Honeywell / Searchpoint Optima Plus
This gas detector is rated IP66/67 for dust and water ingress. It functions effectively across a temperature range from -40 °C to 65 °C. The device offers an output signal of 4-20 mA and features a measuring range of 0-100% LEL, calibrated specifically for methane with a response time of less than 3
Honeywell / 301EM Series
This sensor operates within a temperature span of 0 °C to 40 °C and can withstand humidity levels up to 95% RH without condensation. Its warm-up period is 15 minutes, and it achieves a response time of 60 seconds. With a resolution of 1 ppm and an accuracy of ± 40 ppm at 500 ppm, it ensures reliable
Honeywell / 301EM Series
Designed for reliable operation, this gas detection expansion module operates with an input voltage frequency of 50/60 Hz. It weighs 2.26 lbs and has a current rating of 2 A at 29 Vdc. The device operates efficiently within a temperature range of 0°C to 40°C and can function in humidity levels from
Honeywell / Sensepoint XCD
The SPXCDULNFX flammable gas detector features an IP66 rating and can function within a temperature span of -40°C to 65°C. The device supports a continuous humidity range of 20-90% RH and intermittent levels of 0-99% RH. It utilizes a catalytic bead sensor capable of detecting methane concentrations
Honeywell / XNX Universal Transmitters
This electrochemical sensor features a housing made from 316 stainless steel, ensuring durability in various environments. It operates efficiently between 90 to 110 kPa and has a response time of 15 seconds. An IP66 rating indicates solid protection against dust and water, while a NEMA 4X enclosure
Honeywell / Sensepoint XCD
As a component aimed at detecting oxygen, the SPXCDTMO12 supports a response time of 30 seconds. The device utilizes a digital communication protocol of RS-485 Modbus RTU and provides an analog output of 4–20 mA via a 3-wire connection. Additionally, it is rated IP66 for protection against dust and
Honeywell / Sensepoint XCD
This fixed gas detector operates on either 24 VAC or 24 VDC, making it versatile for various applications. It features an analog output interface using a 4 to 20mA loop, and it is encased in a durable polycarbonate material suitable for NEMA 4 environments. It has a weight of 1.1 lbs and can functio
Honeywell / Sensepoint XCD
This module is designed to function efficiently across a wide operating temperature range from -40°C to 65°C. It features an IP66 rating, ensuring protection against dust and water ingress. The module includes three programmable relay outputs and communicates via an RS-485 Modbus RTU interface.