966 results
Honeywell / Other
The pressure transducer offers exceptional linearity of ±0.10% full scale and an impressive hysteresis of ±0.05% full scale. It remains hermetically sealed and possesses an IP68/NEMA 6P rating, making it resistant to harsh environmental conditions. With a compensated operating temperature range from
Honeywell / Other
This device accommodates an input voltage frequency of 50/60 Hz and operates at a current rating of 500 mA. The unit is functional across a temperature range of -20°C to 50°C and can withstand humidity levels from 0 to 95% relative humidity, ensuring reliability in diverse environments. Networking c
Honeywell / Other
The pressure transducer functions accurately within a temperature range of 0 to 40 degrees Celsius for operation and can be stored between 0 and 50 degrees Celsius. It can handle relative humidity levels of up to 80% and is designed for a clean indoor environment without corrosive agents. Installati
Honeywell / Other
Designed specifically for non-hazardous environments, this flame detector test lamp features a replaceable H3 bulb (part number FSL100-TLBU) and includes a carrying case along with a universal charger (part number FSL100-TLCH). It takes approximately 4 hours to charge (up to 6 hours maximum) and is
Honeywell / Other
This device weighs 1.06 lbs and is built to perform in temperatures from -20°C to 40°C, with humidity levels acceptable from 20% to 90% RH. It provides a 4-20 mA analog output signal and is equipped with a backlit 122 x 32 dot display along with a green status LED. A six-function touch-sensitive key
Honeywell / Other
This transducer is temperature compensated across a range of 15°C to 71°C and exhibits a high degree of accuracy with ±0.10% full scale measurement. The device also features linearity and hysteresis ratings of ±0.10% and ±0.05% full scale, respectively. Its robust construction includes a case made f
Honeywell / Other
Weighing in at 1.76 lbs, this transmitter supports a humidity range of 0-90% RH without condensation. The housing is finished in black, built from painted steel, ensuring durability. The MIDAS-T-004 operates with a maximum power consumption of approximately 5.0 W (12.95 W with pyrolyzer).
Honeywell / Other
This load cell exhibits a non-linearity accuracy of ±0.1% of full scale and a hysteresis of ±0.08%. It operates effectively within a temperature range of -54°C to 121°C, with temperature compensation guaranteed between 15°C and 71°C. The output signal is non-amplified, providing 3 mV/V ±0.5% FS, sui
Honeywell / Other
The sensor operates under a pressure rating of 50 PSI. It functions correctly from 0 to 40 degrees Celsius, with storage conditions also between 0 and 50 degrees Celsius. This unit maintains performance at humidity levels of up to 80% in both operating and storage environments, provided there is no
Honeywell / Other
This load cell operates effectively within a temperature span of -54°C to 121°C and compensates for variations from 15°C to 71°C. It features a bridge resistance of 350 Ω and delivers standard output ranging from 2-3 mV/V, contingent upon load capacity. With a maximum load capacity of 150% of the fu