967 results
Honeywell / Other
This detector transmitter has a weight of 7.72 lbs and features a detection range of 5-40 meters. It can function across a voltage rating of 18-32V DC while maintaining performance from -40°C to 65°C in temperature and 0-99% relative humidity. The unit has an IP66/67 rating, confirming its water and
Honeywell / Other
This gas detector features an IP66 rating, ensuring protection against dust and water ingress. The operating temperature range is -40°C to 65°C, with a specific range of -20°C to 55°C when using a catalytic sensor. It has three relay outputs providing 5 amps at 250 VAC and supported communication th
Honeywell / Other
With a weight of 2.33 lbs, this sensor functions at a voltage rating of 12 VDC and utilizes infrared sensing technology. It measures refrigerant concentrations within a range of 0 to 1000 ppm, with a detailed resolution of 1 ppm. Its enclosure is made from durable ABS-Polycarbonate, offering adequat
Honeywell / Other
This controller accommodates a voltage input range of 17-27 VAC or 18-36 VDC. It operates effectively in temperatures ranging from -20 °C to 50 °C, making it suitable for diverse environments. The unit can communicate using the RS-485 Modbus protocol, and it is capable of supporting up to 96 wired a
Honeywell / Other
This device utilizes an electrochemical cell sensor and generates a 4 to 20 mA analog loop output. It has a charcoal polycarbonate enclosure rated IP65, making it resistant to dust and water ingress. The detector can function effectively at temperatures between -20 °C and 50 °C and weighs only 1.2 l
Honeywell / UDC1200
This unit operates on a power range of 90 to 264 VAC and can function at frequencies between 50 and 60 Hz. It features both a relay output and a 4-20 mA linear DC output in its option slots. Designed to operate at ambient temperatures from 0°C to 55°C, it is also rated for storage between -20°C and
Honeywell / Other
Equipped with one control loop and an auxiliary input, this digital controller offers two base options: relay output alongside linear DC output. Communication is facilitated via Ethernet, and it can maintain operation within an operating temperature range of 0°C to 55°C. This device can be installed
Honeywell / Other
The VBF5013B1029 features a 4-inch pipe size and weighs 130.9 lbs. It operates under a maximum pressure of 240 PSI and can handle medium temperatures ranging from -30°C to 121°C. This valve utilizes cast iron for the body and has a stem made of 316 stainless steel, ensuring durability.
Honeywell / Other
This globe valve features a 3-way body pattern, with unique flow characteristics—an equal percentage flow from Port A to AB and linear flow from Port B to AB. The valve is rated for body pressure up to 360 psi and provides ANSI Class IV leakage performance at Port A to AB and ANSI Class III at Port