966 results
Honeywell / Other
This device accommodates an input voltage frequency of 50/60 Hz and operates at a current rating of 500 mA. The unit is functional across a temperature range of -20°C to 50°C and can withstand humidity levels from 0 to 95% relative humidity, ensuring reliability in diverse environments. Networking c
Honeywell / Other
This device weighs 1.06 lbs and is built to perform in temperatures from -20°C to 40°C, with humidity levels acceptable from 20% to 90% RH. It provides a 4-20 mA analog output signal and is equipped with a backlit 122 x 32 dot display along with a green status LED. A six-function touch-sensitive key
Honeywell / Other
Weighing in at 1.76 lbs, this transmitter supports a humidity range of 0-90% RH without condensation. The housing is finished in black, built from painted steel, ensuring durability. The MIDAS-T-004 operates with a maximum power consumption of approximately 5.0 W (12.95 W with pyrolyzer).
Honeywell / Other
The sensor operates under a pressure rating of 50 PSI. It functions correctly from 0 to 40 degrees Celsius, with storage conditions also between 0 and 50 degrees Celsius. This unit maintains performance at humidity levels of up to 80% in both operating and storage environments, provided there is no
Honeywell / Other
This load cell operates effectively within a temperature span of -54°C to 121°C and compensates for variations from 15°C to 71°C. It features a bridge resistance of 350 Ω and delivers standard output ranging from 2-3 mV/V, contingent upon load capacity. With a maximum load capacity of 150% of the fu
Honeywell / Other
This kit operates effectively in environments with temperatures between 0 and 40 degrees Celsius. It can be stored safely in conditions ranging from 0 to 50 degrees Celsius. The mounting bracket supports a maximum relative humidity of 80%, both during operation and storage, while being functional at
Honeywell / Other
This pressure transducer maintains operational integrity with a maximum relative humidity of 80% in non-condensing environments. It supports both storage and operating conditions at altitudes up to 1000 meters above sea level. The storage temperature can range from 0 to 50 degrees Celsius, ensuring
Honeywell / Other
This load cell operates effectively within a temperature range of 0 to 40 degrees Celsius and maintains performance in storage between 0 to 50 degrees Celsius. The device allows for a maximum relative humidity of 80% when operating or in storage. It is intended for environments up to 1000 meters abo
Honeywell / Other
Designed to operate effectively in harsh environments, the S3KUL2 transmitter is IP66 rated, ensuring excellent protection against dust and water ingress. It functions within a wide temperature range from -40°C to 55°C, and accommodates humidity levels between 20% to 90% (non-condensing). The maximu
Honeywell / Other
This gas sensor assembly has a designated detection range of 0 to 25% volume for oxygen. It operates effectively at temperatures from -20°C to 40°C. The device is compatible with primary controllers including the 301EM-20, 301C, and 301-D2 series and can maintain performance with a maximum cable dis