969 results
Honeywell / Other
This actuator has a maximum operating pressure of 5 PSI and is rated for 120 V AC at 60 Hz. It features quick opening in 26 seconds and rapid closing in less than one second, making it suitable for dynamic control scenarios. Its die-cast aluminum body provides robust durability, while feedback indic
Honeywell / Other
Designed with a black solenoid actuator and an aluminum valve body, this unit can withstand inlet pressures up to 500 mbar (7 psig). It has a size 2 connection with two 1 inch NPT flanges, providing flexibility in integration. The quick opening and closing mechanism allows for efficient control, whi
Honeywell / Other
This detector transmitter has a weight of 7.72 lbs and features a detection range of 5-40 meters. It can function across a voltage rating of 18-32V DC while maintaining performance from -40°C to 65°C in temperature and 0-99% relative humidity. The unit has an IP66/67 rating, confirming its water and
Honeywell / Other
This gas detector features an IP66 rating, ensuring protection against dust and water ingress. The operating temperature range is -40°C to 65°C, with a specific range of -20°C to 55°C when using a catalytic sensor. It has three relay outputs providing 5 amps at 250 VAC and supported communication th
Honeywell / Other
This load cell operates effectively within a temperature range of 0 to 40 degrees Celsius and maintains performance in storage between 0 to 50 degrees Celsius. The device allows for a maximum relative humidity of 80% when operating or in storage. It is intended for environments up to 1000 meters abo
Honeywell / UDC1200
This unit operates on a power range of 90 to 264 VAC and can function at frequencies between 50 and 60 Hz. It features both a relay output and a 4-20 mA linear DC output in its option slots. Designed to operate at ambient temperatures from 0°C to 55°C, it is also rated for storage between -20°C and
Honeywell / Other
Equipped with one control loop and an auxiliary input, this digital controller offers two base options: relay output alongside linear DC output. Communication is facilitated via Ethernet, and it can maintain operation within an operating temperature range of 0°C to 55°C. This device can be installed
Honeywell / Other
This globe valve features a 3-way body pattern, with unique flow characteristics—an equal percentage flow from Port A to AB and linear flow from Port B to AB. The valve is rated for body pressure up to 360 psi and provides ANSI Class IV leakage performance at Port A to AB and ANSI Class III at Port
Honeywell / Other
Capable of handling 4 cool output stages, this logic panel operates within a frequency range of 50 to 60 Hz. It consumes 8 VA of power and connects using 1/4 in. quick-connect male terminals. Suitable for input signals ranging from 1 to 16 VDC, it can function effectively in temperatures from -40°C
Honeywell / Other
This economizer module operates effectively with a logic module and is designed to support a range of sensors to optimize air quality management. It functions between a minimum temperature of 0 degrees Celsius and a maximum temperature of 40 degrees Celsius, displaying reliable performance in varied