Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Designed for robust applications, this circuit breaker holds an interrupt rating of 22 kAIC at 240 VAC. It accommodates a frequency range between 50 Hz and 60 Hz. The terminal type is specifically for load-side connections, and it is categorized under the F Frame type, which influences its physical
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This auxiliary switch kit facilitates left-side mounting and utilizes pigtail leads for connection. Operating effectively within a frequency range of 50 to 60 Hz, it is constructed to function within temperature limits from 0 °C to 40 °C during both operation and storage.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Intended for three-phase use, the FDC3225 circuit breaker incorporates fixed thermal and magnetic trip mechanisms. It exhibits robust interrupt ratings: 200 kAIC at 240 VAC, 100 kAIC at 480 VAC, and 35 kAIC at 600 VAC, along with a 22 kAIC rating for 250 VDC systems, making it suitable for various i
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This motor circuit protector features three poles and can operate at a maximum voltage of 600 VAC and 250 VDC. The device includes a magnetic trip range from 500 A to 1000 A for efficient protection. Its interrupting capacity ratings are 65 kAIC at 240 VAC, 35 kAIC at 480 VAC, and 18 kAIC at 600 VAC
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This three-pole circuit breaker features an F-frame size and utilizes load side terminals for secure connections. It supports a frequency range of 50 to 60 Hz and has a T186 trip type. Notably, it can handle high fault levels, with a 200 KAIC interrupt rating at 240 VAC and a 100 KAIC rating at 480
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Configured with two poles, the HFD2110 molded-case circuit breaker can handle both AC and DC situations. Its fixed thermal and magnetic trip type ensures effective protection against overloads and faults. The device features an interrupt rating of 65 kAIC at 480 VAC, catering to demanding environmen
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This product features two poles and is characterized by a fixed thermal-magnetic trip unit. It possesses a high interrupting capacity, capable of 100 kAIC at 240 VAC and 65 kAIC at 480 VAC. Designed for 50/60 Hz operation, it is suitable for mounting on a panelboard and utilizes a bolt-on connection
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features a magnetic trip unit that delivers instantaneous trip functions. With a current breaking capacity of 65 kiloamperes at 480 Volts AC, it's designed to handle demanding situations effectively. The breaker consists of three poles and has a feed-thru connection type, ideal
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This GHB circuit breaker operates efficiently with a voltage rating of 480Y/277 volts AC and 125/250 volts DC. It is rated for 50/60 hertz operation and delivers an interrupt rating of 14 kAIC at 480Y/277 V AC and 65 kAIC at 240 V AC. It accommodates wire sizes from AWG #10 to 1/0 for both copper an
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Designed to integrate with Type MDL, HMDL, and HMDLDC breaker frames, the MT3800T features a thermal magnetic trip system. It operates with a current rating of 800 A and includes three poles, designed for both long-time and instantaneous trip functions. Its operational temperature limits range from