Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Featuring a compact F frame design, this device includes two poles and is rated for an impressive 150 Amps. It accommodates a frequency range between 50 Hz and 60 Hz. The circuit breaker is equipped with high interrupting capabilities, rated at 100 KAIC for 240 VAC and 65 KAIC for 480 VAC, ensuring
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker operates with voltage ratings of 600 VAC and 250 VDC. It offers interrupting ratings of 65 kAIC at 240 VAC, 35 kAIC at 480 VAC, and 18 kAIC at 600 VAC. The protection is ensured by fixed thermal and magnetic trip units providing long-time and instantaneous (LI) trip functions.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This accessory, suitable for Frame J-K size applications, includes a magnetic trip range of 45 to 150 A. It operates at an AIC rating of 65 kA at 480V and supports a feed-thru connection type. Designed for an environment with humidity levels up to 80% (non-condensing), it is installed at an altitude
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This accessory features LSIG trip functions, providing long-time, short-time, instantaneous, and ground fault protection. It operates at a rated voltage of 600 VAC and covers frequency parameters between 50 Hz and 60 Hz. This model is equipped with true RMS sensing for accurate readings and utilizes
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker accessory features three poles and is designed with a J-K frame type. Its AIC rating is rated at 65 KA at 480 V, ensuring significant fault current handling capability. The humidity tolerance is set at 80% for both operating and storage conditions, making it versatile for variou
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This single-pole circuit breaker is suitable for both AC and DC applications, with a maximum voltage rating of 480Y/277 VAC and 125/250 VDC. Its fixed thermal and fixed magnetic trip type ensures swift response to electrical faults. With an interrupting capacity of 14 kAIC at 277 VAC and operational
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
With a J-K frame size, this motor circuit protector operates at a rated voltage of 600 V for AC and 250 V for DC. The magnetic trip range extends from 300 A to 1000 A. It has impressive interrupting ratings: 65 kA at 480 VAC, 25 kA at 600 VAC, and 42 kA at 250 VDC. The device is bolted for secure mo
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
The CHLD3600F from Eaton's Series C Circuit Breakers utilizes a sturdy L-Frame design and is rated for a current of 600 Amps. It has three poles and supports a significant interrupting capacity of 65 kAIC at 480VAC. The trip mechanism is based on fixed thermal and fixed magnetic characteristics, ens
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Part of the Series C line, the FD2020 circuit breaker supports an interrupting capacity of 65 KAIC at 240 VAC and 35 KAIC at 480 VAC. It is equipped with both fixed thermal and magnetic trip types, providing LI (Long-Time and Instantaneous) trip functions. Its operational frequency ranges from 50 Hz
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker consists of three poles arranged in an F frame size. With a fixed thermal and fixed magnetic trip type, it ensures reliable protection against overloads and short circuits. The interrupt rating is 18 kAIC at 240 VAC and 14 kAIC at 480 VAC, providing substantial fault current sup