GE Fanuc Emerson / Spectra
Constructed from low carbon steel, this enclosure is designed for surface mounting and guarantees compliance with CSA and UL standards. It operates efficiently within the frequency range of 50 to 60 Hertz and is suitable for use in temperatures spanning from 32 to 104 degrees Fahrenheit. Compatible
GE Fanuc Emerson / Spectra
This circuit breaker has three poles and employs a Long-Time/Instantaneous (LI) trip function. It includes lug terminals for easy installations, though it does not provide protective relays or current metering features. The trip style is fixed and cannot be swapped out.
GE Fanuc Emerson / Spectra
This circuit breaker operates at an AC voltage of 480 VAC. The thermal magnetic protection class ensures reliable disconnection during overload situations, incorporating both long-time and instantaneous trip functions. It features a bolt-on connection for easy installation and possesses an AIC ratin
GE Fanuc Emerson / Spectra
Designed to trip remotely when the voltage drops below 70% of its rated value, the TEDUV2 is compatible with multiple breaker frames including TEB, TEC, TED, THED, THLC1, and TB1. This unit has a single pole configuration and is field-installed for ease of use. The interrupt rating varies depending
GE Fanuc Emerson / Spectra
This device operates within a frequency range of 50 to 60 Hertz. The TEYD2040B supports wire sizes from 10 to 4 AWG. It features long-time and instantaneous trip functions (LI) for enhanced protective capabilities. With an interrupt rating of 65 kA for 120/240 Volts AC and 25 kA for 277/480 Volts, i
GE Fanuc Emerson / Spectra
This circuit breaker features two poles and is compactly designed for 1-phase systems. It is rated for a maximum of 480 VAC for AC applications and 250 VDC for DC applications. The device includes thermal magnetic protection and can handle an interrupting current up to 18 kA at 480 VAC, making it a
GE Fanuc Emerson / Spectra
The TED113100 provides thermal magnetic protection, featuring a non-interchangeable trip style. It is designed to manage AC voltages up to 277 VAC and is suitable for reverse feed applications. Note that current metering and protective relays are not included in this model. The long-time trip settin
GE Fanuc Emerson / Spectra
This product is designed for compatibility with breaker families such as Spectra and Power Break Series. Configured with two poles, it can accommodate a trip range from 680A to 2295A. The rating plug features an interrupting capacity of 65 kA at 480V AC, with an adjustable short-time pickup and meet
GE Fanuc Emerson / Spectra
Constructed with thermal-magnetic trip technology, this circuit breaker is rated for 18 kA interruption at 480 V. The TED134090 model supports both long-time and instantaneous protection functions, making it suitable for various indoor applications and environments. Its bolt-on mounting style allows
GE Fanuc Emerson / Spectra
Designed for both operational and storage environments, this rating plug can function optimally within a temperature range from 0°C to 40°C and supports a humidity level of 80% without condensation. It is compatible for installation at altitudes up to 1000 meters above sea level.