404 results
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker supports a rated current of 40 A and comes in a Frame F size. With three poles, it features load side terminals and operates efficiently at frequencies between 50 Hz and 60 Hz. Its interrupt capacity is rated at 100 kAIC for 240 VAC and 65 kAIC for 480 VAC, ensuring robust perfo
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Designed for versatility, this breaker features three poles and provides reverse feed protection functions. It connects through feed-thru and includes terminal lugs for load-side connections and a busbar for line-side connections. It operates efficiently at frequencies ranging from 50 to 60 Hertz, c
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker trip unit operates within a voltage rating of 600 VAC and includes a fixed trip type labeled T185. It is designed for 3-phase systems and effectively handles frequencies from 50 to 60 Hz. Rated for an ambient temperature of up to 40 °C, it provides both long-time thermal and ins
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This unit features three poles and operates under a thermal-magnetic trip mechanism, known as the TI85 type. It supports installation at altitudes up to 1000 meters above sea level and is designed to function within specific temperature limits of 0°C to 40°C for both operation and storage.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Belonging to the Series C Circuit Breakers, the FD3110 features three poles and an F frame design. This model includes a thermal magnetic trip unit that provides long-time overload and instantaneous short-circuit protection. The circuit breaker has impressively high interrupt ratings of 65 kA at 240
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
The trip unit features three poles and includes long-time and instantaneous tripping functions (LI). With a frequency rating between 50 and 60 Hertz, this thermal magnetic trip unit is compliant with UL standards and is compatible with multiple circuit breaker frames, including CKD and KD.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Designed with fixed thermal and magnetic trip functions, this breaker operates efficiently within a frequency range of 50 to 60 Hz. It features a 100% rating and is constructed with three poles for robust circuit management. The connection type is bolt-on, suitable for easy installation, and it meet
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features a 2-pole design and supports a frequency range from 50 Hz to 60 Hz. It operates effectively at a rated current of 100 A with an interrupt rating of 42 KAIC at 240 VAC. The breaker is constructed for load side terminals, making it suitable for various installation types.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker is equipped with a fixed thermal and fixed magnetic trip unit. It features a connection type of bolt-on and can handle a DC voltage of 250 V. With an interrupt rating of 100 kA at 240 V and 65 kA at 480 V, it provides substantial protection against overcurrent conditions. The un
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features a compact design with an F frame and supports a panel mount installation. The device includes a thermal magnetic tripping unit for enhanced protection, and its load side terminal connection utilizes lugs. With a breaking capacity of 35 kiloamperes at 277 volts AC and 18