Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This MCCB accessory consists of three poles and operates efficiently within a magnetic trip range of 750 to 2500 A. It is UL Listed, ensuring compliance with safety standards. The device is specifically intended for motor protection, and it connects via lugs while being mounted on panels.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This undervoltage release mechanism features a frequency range between 50 Hz and 60 Hz. It is mounted on the left pole and employs an F frame type design. The device ensures reliable operation within specified temperature limits, making it suitable for various environments.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Designed with three poles, the FD3080 features a T186 trip type and is suitable for a frequency range of 50 to 60 Hz. Its interrupt ratings are notable: 35 KAIC at 480 V and 65 KAIC at 240 V, ensuring significant protection against fault conditions. This circuit breaker utilizes load side terminal c
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This model fits in the Series C Circuit Breakers and has a frame type designated as F. It supports voltages up to 600 VAC and 250 VDC while providing significant interrupt ratings. The breaker can interrupt 18 kA at 240 VAC and maintains a consistent performance with 14 kA at both 480 VAC and 600 VA
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
With a robust operating temperature range from 0°C to 40°C, the A1X5PK is tailored for demanding environments. This unit also supports storage conditions between 0°C and 40°C, while maintaining operation in humidity levels up to 80% without condensation. Its suitable installation altitude reaches up
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This accessory, suitable for Frame J-K size applications, includes a magnetic trip range of 45 to 150 A. It operates at an AIC rating of 65 kA at 480V and supports a feed-thru connection type. Designed for an environment with humidity levels up to 80% (non-condensing), it is installed at an altitude
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This device operates within the J-K frame size and utilizes a trip type designated as T266. The protection mechanism incorporates both thermal and magnetic features, allowing for effective interruption. It supports a magnetic trip range of 2500 A to 5000 A and maintains functionality across a freque
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This trip unit is compatible with J-K frame types and includes three poles for effective circuit management. It operates at a rated voltage of 600 VAC. The unit's operational temperature range spans from 0°C to 40°C, ensuring stability under various conditions. It maintains the same temperature rang
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This accessory features three poles and is rated for a voltage of 600 V in three-phase applications. The device contains a magnetic trip range between 115 and 170 Amps. It is rated for an AIC of 65 kA at 480 V, providing robust protection.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features three poles and incorporates a T186 trip mechanism to ensure reliable operation. With a robust interrupt rating of 14 KAIC at 480 VAC and 18 KAIC at 240 VAC, it delivers necessary safety during fault conditions. The F frame design allows for optimal installation in pane