714 results
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This undervoltage release operates on pigtail leads and utilizes an electromagnetic mechanism for its functioning. The device conforms to standards set by IEC and UL, ensuring compliance and safety in applications. Its reset method is electrical restore, and it has an insulation rating of Class B. D
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
With two poles and a T186 trip type, the FDB2030 is suitable for a variety of systems. The breaker has a frame type designated as Frame F and allows for connections via the load side terminal. It delivers an interrupt rating of 14 KAIC at 480 V and 18 KAIC at 240 VAC, making it effective for protect
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker is structured with three poles and operates effectively in 3-phase systems. It has a voltage rating of up to 600 VAC and 250 VDC. The KDC3300’s interrupting ratings are impressive: 200 kAIC at 240 VAC and 100 kAIC at 480 VAC. The unit features a K-frame design and includes termi
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Designed with an F frame type, the EDB3225 features a trip type of T186 and is rated for an interrupt capacity of 22 KAIC at 240 VAC. It operates within a frequency range from 50 Hz to 60 Hz, with load-side terminals facilitating connection.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This shunt trip device operates within a minimum DC control voltage of 220 VDC and a maximum of 250 VDC. It also supports a control voltage range from 415 VAC to 600 VAC, ensuring compatibility with various setups. This model is designed specifically for frame types FD and is compatible with FDB, HF
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker operates at a fixed trip unit and is suitable for three-phase systems. It supports both long-time and instantaneous trip functions, enhancing its protective capabilities. The KT3200T is UL listed and has a frequency rating of 50/60 Hz, making it compliant with standard electrica
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker is a single-pole unit with fixed thermal/magnetic trip mechanisms, supporting both long-time and instantaneous trip functions. Its interrupt ratings stand at 14 kAIC for 480 V and 18 kAIC for 240 V. The EHD1045 is designed for use in single-pole panelboards, utilizing a feed-thr
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This undervoltage release mechanism is compatible with multiple frame types, including LDB, LD, HLD, LDC, CLD, CHLD, CLDC, MDL, HMDL, MDLB, HMDLB, E2L, E2LM, E2M, and E2MM. Operational and storage temperature ranges for this device span from 0°C to 40°C, with humidity levels maintained at a maximum
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
With three poles, the EDS3175 is structured to function in three-phase configurations. It offers an interrupting rating of 42 kAIC at 240 VAC to ensure reliable performance during fault conditions. Its thermal magnetic trip mechanism has a long-time and instantaneous (LI) function, supporting both o
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Designed with a T186 trip type and compatible with both AC and DC systems, the GHB2100 circuit breaker operates efficiently at a minimum frequency of 50 Hz and a maximum frequency of 60 Hz. The unit is capable of interrupting currents of 14 kAIC at 480Y/277 VAC and 65 kAIC at 240 VAC.