50 results
Horner Electric / PLC I/O
Featuring a robust design, this temperature module utilizes 16-bit integrating A/D conversion and can update at a rate of 50 channels per second. Typical power consumption is 75 mA at 5V DC, ensuring efficient operation. The device operates effectively within a temperature range of 0 to 60°C and wit
Horner Electric / PLC I/O
The HE697THM160 is an input module designed for the Series 90-70 Thermocouple devices, accommodating 16 channels. The operational environment allows for relative humidity ranging from 5% to 95% without condensation. It features both internal and external cold junction compensation, with a future upg
Horner Electric / PLC I/O
This high-resolution thermocouple module supports types J, K, N, T, E, R, S, B, C, and X. It boasts an impressive input impedance exceeding 20 Mohms and operates effectively within a temperature range of 0 to 60 degrees Celsius. The device features an A/D conversion time of just 5 milliseconds, scan
Horner Electric / PLC I/O
This isolated RTD input module accommodates up to six channels and is compatible with several RTD types such as Pt-100 and Cu-10. Typical sensor excitation current is about 330 µA, and it features an input impedance greater than 1000 MΩ. The device provides an 18-bit integrating A/D conversion with
Horner Electric / PLC I/O
The HE693ADC405 is an analog input module featuring a ±10 Volt input range with four channels available for data acquisition. It requires I/O connections of 4 %AI, 4 %AQ, and 16 %I. The device operates efficiently with a steady-state power consumption of 0.4W at 5V and 2.16W at 24V, drawing 80mA and
Horner Electric / PLC I/O
This module supports up to six channels with a wide selection of thermocouple types, including J, K, N, T, E, R, S, B, and C. It showcases considerable isolation levels, with channel-to-channel isolation of ±250V AC and backplane isolation rated at ±1500V AC. The temperature measurement capabilities
Horner Electric / PLC I/O
This output module features four analog outputs, allowing for effective signal processing. It operates within an output signal range of either 0–20 mA or 4–20 mA and achieves a D/A resolution of 14 bits. This module retains high accuracy, achieving a linearity error of ±0.10% in 4-20 mA mode. Isolat
Horner Electric / PLC I/O
This module supports an impressive resolution of 18 bits, with 13 bits plus sign being usable for applications. It has an excellent common mode rejection rate exceeding 100 dB, ensuring robust performance in various settings. The device requires specific I/O configurations including 4 %AI, 4 %AQ, an
Horner Electric / PLC I/O
The HE693DAC410 module is an analog output component from Horner Electric's PLC I/O series, designed to provide four output channels. It facilitates an output voltage range of +/- 10 volts DC and operates with a digital-to-analog resolution of 13 bits plus sign. This module requires an I/O configura
Horner Electric / PLC I/O
A component of the PLC I/O series, the HE670ADC830 module consists of 8 individual channels with selectable input ranges of either 0 to 10 VDC or -10 to +10 VDC. It has an input impedance of 1 Mohm and delivers a resolution of 12-bits, allowing for precision in data measurement. The device operates