408 results
Omron / 3G2
This module operates with an insulation resistance of at least 20 MΩ at 500 VDC and weighs 500 g. It is capable of withstanding shocks of 147 m/s² (15 G) and has a vibration resistance range of 10 to 57 Hz at an amplitude of 0.075 mm. Designed to operate in temperatures from -10°C to 55°C, it can al
Omron / 3G2
The 3G3HV-A4150-CE operates on a 3-phase input system and can output voltages from 0 to 460 V. It functions effectively within an ambient temperature range of -10°C to 50°C and utilizes either fan-assisted or passive cooling for heat management. The device is panel or wall-mounted and has a protecti
Omron / 3G2
This model allows for an adjustable frequency range from 0.1 to 400 Hz with a frequency accuracy of ±0.01% digitally and ±0.5% analog. The enclosure type is an open chassis with an IP20 rating, and it operates within an ambient temperature of 14 to 122°F (-10 to +50°C). Equipped with motor overload
Omron / 3G2
This link adapter operates within a power supply requirement of 100 to 120 VAC or 200 to 240 VAC, and 12 to 24 VAC/DC. The operating voltage can range between 85 to 132 VAC, 170 to 246 VAC, and 10.2 to 26.4 VAC/DC. This Link Adapter supports auxiliary input for backup power and includes repeater inp
Omron / 3G2
This Omron auxiliary unit is specifically designed for expansion input/output racks. It operates smoothly with Omron C1000, C2000, and C200H programmable controllers. It maintains a standard insulation resistance and is built to endure various conditions, including appropriate temperature and humidi
Omron / 3G2
This input unit can handle 16 points organized into 2 circuits with 8 points common for flexible configuration. The input current is typically 10 mA at 100 VAC, with a maximum ON voltage of 120 VAC. The OFF voltage is capped at 40 VAC, and it features an ON response time of up to 35 ms and an OFF re
Omron / 3G2
This unit facilitates broadcasting communication over a distance of 500 meters, accommodating up to 32 separate PC link units. It allows for link relay bits ranging from 32 to 512 bits, ensuring ample data transfer capabilities. Diagnostic features include a CPU watchdog timer and CRC transmission e
Omron / 3G2
This inverter model operates efficiently within an input voltage range of 200 to 240 VAC, supporting a power rating of 1.1 kW. It protects against various electrical issues, including overload and short circuit conditions. The output frequency can be adjusted from 0 to 400 Hz, and the inverter maint
Omron / 3G2
This module supports 32 input points, with a configuration of 8 points per common across 4 circuits. The input current is typically 10 mA at 24 VDC, responding with an ON voltage of 10.2 VDC minimum and an OFF voltage of 3.0 VDC maximum. The unit has a maximum OFF and ON response time of 15 ms. It h
Omron / 3G2
This device includes a total of 16 input points organized into 8 points per common circuit across 2 circuits, making it versatile for different configurations. The ON voltage is set at a minimum of 10.2 VDC, while the OFF voltage reaches a maximum of 3.0 VDC. The response times for both ON and OFF s