68 results
Schneider Electric / FA Series
A member of the FA Series, this circuit breaker is engineered with a thermal magnetic trip system and a breaking capacity code of A. It can handle a magnetic hold current of 275 A and a tripping current of 600 A. Designed for I Line mounting, it fits seamlessly into electrical panels. The circuit br
Schneider Electric / FA Series
The FA100DS circuit breaker enclosure accommodates a minimum current rating of 15 A and a maximum of 100 A. With IP52 protection, it is prepared to handle moisture and dust. Its operating temperature range is from 0 to 40 degrees Celsius, with a maximum humidity of 80% for both operation and storage
Schneider Electric / FA Series
This unit is designed as a 3-pole circuit breaker with a breaking capacity code of A. It includes magnetic hold and tripping currents rated at 400 A and 850 A, respectively. The FAL320401021 is UL Listed for safety compliance and is installed using a unit mounting method.
Schneider Electric / FA Series
This circuit breaker model features a breaking capacity code of A and is mounted using a unit mount mode. It handles a magnetic hold current of 275 A and activates tripping at 600 A. The connections consist of load lugs and support ABC phase configuration. Compact in size, it has dimensions of 6.4 i
Schneider Electric / FA Series
With a frame type designated as F, this circuit breaker incorporates thermal magnetic trip technology. It is rated for 480 V and has a maximum interrupt capacity of 18 kA at that voltage. Humidity levels for operation and storage can reach up to 80% non-condensing, and it functions in ambient temper
Schneider Electric / FA Series
This circuit breaker is operated with thermal magnetic trip technology. The unit has a rated current of 50 A and includes three poles. With a breaking capacity code of A, the device supports connections via Lugs for load applications. It has a magnetic hold current of 400 A and a magnetic trip curre
Schneider Electric / FA Series
Designed with three poles, the FAP36100 circuit breaker accommodates phase connections in an ABC configuration. It features a breaking capacity code of A and has a unit mount installation mode. The device exhibits a magnetic hold current of 900 A and a tripping current of 1700 A. This circuit breake
Schneider Electric / FA Series
This circuit breaker uses thermal magnetic technology to trip. Rated for 15 Amps, it can handle a magnetic hold current of 275 A and a magnetic tripping current of 600 A. Its compact design offers a height of 6.4 inches, a width of 4.5 inches, and a depth of 4.13 inches, suitable for unit mounting.
Schneider Electric / FA Series
The FA26030AC circuit breaker has a breaking capacity code of A and operates with thermal magnetic trip technology. It is suitable for AC phase applications and is mounted in an I line configuration. The device has a magnetic tripping current rating of 600 A, making it effective for protecting elect
Schneider Electric / FA Series
The FA22090AB circuit breaker operates on thermal magnetic trip technology and has a line-rated current of 90 A. This device includes two poles and a breaking capacity code of A, suitable for mounting in an I-line configuration. The magnetic hold current is rated at 900 A, with a magnetic tripping c