507 results
Schneider Electric / PowerPact
This circuit breaker utilizes thermal magnetic trip technology and has a breaking capacity rated at 65 kA, classified under code G. The unit operates effectively across 50/60 Hz frequency ranges and withstands impulse voltages up to 8 kV. It supports a magnetic tripping current of 2400 A and a hold
Schneider Electric / PowerPact
This circuit breaker has a magnetic hold current of 1200 A and is designed to be installed in a unit mount configuration, with lugs positioned at both ends. It measures 6.47 x 4.5 x 3.93 inches and allows for a tightening torque of 28 N·m. With an interrupting capacity of 100 kA at 208Y/120 V AC, an
Schneider Electric / PowerPact
Designed for P and R-frame circuit breakers, this trip unit supports LI protection functionalities. It operates effectively within an ambient temperature range of -25 to +60°C, and its IP20 rating provides a level of protection against solid objects. This compact unit has an electrical life of 20,00
Schneider Electric / PowerPact
This circuit breaker features a three-pole configuration and is part of the PowerPacT series. It is equipped with a Micrologic Version 3 electronic monitoring system. This unit operates efficiently across ambient temperatures from -5°C to 40°C, with an interrupting rating of 25 kA and a breaking cap
Schneider Electric / PowerPact
This P-Frame circuit breaker supports a voltage rating of 600 V AC and can operate within a frequency range of 50/60 Hz. It features panel mounting and uses lugs for line and load connections. The certification marks include CSA and UL, ensuring compliance with industry safety standards.
Schneider Electric / PowerPact
This circuit breaker is designed with an electronic ammeter trip unit type and operates at 600 V AC. It has connection points for both line and load via lugs. Rated for 800 A continuous operation, its breaking capacity is classified as G. It includes a micrologic trip unit of 6.0A for enhanced funct
Schneider Electric / PowerPact
This P-frame molded case circuit breaker features a solid state design with electronic trip capabilities. It can accommodate three phases and is compliant with UL and CSA standards. The breaker is rated for 100 kA at 240V, 65 kA at 480V, and 25 kA at 600V, ensuring substantial interruption capabilit
Schneider Electric / PowerPact
Designed with a breaking capacity of 10 kA and a breaking capacity code designated as B, this circuit breaker is suited for standard operational voltages up to 240 V. The device can function effectively within frequencies ranging from 50 Hz to 60 Hz, and supports a rated impulse withstand voltage of
Schneider Electric / PowerPact
This circuit breaker operates at a rated voltage of 240 volts and can handle breaking capacities of 25 kA. It is capable of functioning within a frequency range between 50 Hz and 60 Hz. The unit's rated impulse withstand voltage is 8 kV, making it suitable for various applications.
Schneider Electric / PowerPact
This circuit breaker operates at a rated impulse withstand voltage of 8 kV and is compatible with a network frequency of 50/60 Hz. It features thermal magnetic trip unit technology, with an operating handle control type. The continuous current rating is at 80% of the line rated current, providing op