714 results
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features two poles and provides an interrupting capacity of 100 kAIC at 240 VAC and 65 kAIC at 480 VAC. With a trip type of fixed thermal and fixed magnetic, it delivers effective protection functions categorized as LI (Long-Time and Instantaneous). Operating frequency ranges fr
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker is designed for use in three-phase systems and has fixed thermal and magnetic trip types for effective protection. It features interrupting ratings of up to 65 kAIC at 240 VAC and 14 kAIC at both 480 VAC and 250 VDC, providing reliable fault interruption capabilities. Operating
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker terminal lug kit features a single barrel for each terminal, constructed from plated steel for durability. It has a wide operating temperature range, functioning effectively between -20°C and 70°C. For storage, it can remain intact at temperatures ranging from -45°C to 85°C.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker is of the GDB Type and features a G-frame form factor. It consists of three poles and operates within frequencies ranging from 50 Hz to 60 Hz. The breaker provides significant interrupting capacity, rated at 14 kAIC for 480 volts and 65 kAIC for 240 volts, ensuring reliable circ
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker type is classified as EHD, featuring a 2-pole configuration. It is rated for a current of 20.0 A and a voltage range of 240 VAC to 480 VAC, along with a DC voltage rating of 250 VDC. It has interrupt ratings of 18 kAIC at 240 VAC and 14 kAIC at 480 VAC, ensuring robust performan
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker supports fixed thermal and magnetic trip types, providing both long-time and instantaneous protection features. Its interrupting capacity is rated at 100 kAIC for 240 VAC, 65 kAIC for 480 VAC, and 25 kAIC for 600 VAC. This unit weighs 3.05 lbs and falls within the Series C famil
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features three poles and incorporates a fixed thermal and fixed magnetic trip type for reliable protection. It is rated for a performance interruption of 65 kAIC at 480 VAC. The design accommodates frame size F and is suitable for load side termination, operating within a freque
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker is configured with three poles and operates at a voltage rating of 480 VAC for AC applications and 250 VDC for DC usage. The device has an interrupting capability of 14 kAIC at 480 VAC, 18 kAIC at 240 VAC, and 10 kAIC at 250 VDC. It is capable of handling frequencies from 50 Hz
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Designed for use in three-phase environments, the DOPTMLN module operates efficiently within an input voltage of 0 to 600 VAC, accommodating frequencies between 50 Hz and 60 Hz. This module includes 3 fuses rated at 600 V to ensure protection and performance. It has four terminals for secondary conn
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This three-pole circuit breaker operates effectively within a frequency range of 50 Hz to 60 Hz. The LDC3500's interrupting capacity is rated at 65 kAIC for 240 VAC and 100 kAIC for 480 VAC. Its long-time and instantaneous trip functions ensure adequate protection under various load conditions, whil