Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker consists of 3 poles and incorporates a magnetic contactor. It has an interrupt rating of 35 kA at 480 volts, equipped with a J frame type for robust performance. The unit features feed-thru connectivity and connects via lugs on both line and load sides, allowing for effective in
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
With an interrupting capacity of 35 kA at 480 V AC and 25 kA at 600 V AC, this trip unit ensures effective protection. Additionally, the unit maintains a DC interrupt rating of 22 kA. The frame size is categorized as J/K. This model includes ground fault protection and features an adjustable long-ti
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker consists of two poles and utilizes an F frame configuration. With an interrupt rating of 18 KAIC at 240 VAC and 14 KAIC at 480 VAC, this device is ideal for protecting circuits from overcurrent conditions. It supports an operational frequency between 50 Hz and 60 Hz.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker operates at a frequency of 50 to 60 Hertz and includes a thermal magnetic trip unit. Interrupt ratings are notable, with 35 kA at 277 volts AC and 10 kA at 125 volts DC. The frame type is designated as F, and it allows connections through load side pressure terminals. The device
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Designed with three poles, this J-frame circuit breaker allows for robust 3-phase operation. Interrupting capacities include 200 kA at 240V AC, 100 kA at 480V AC, and 35 kA at 600V AC. This unit mounts easily via a bolt-on connection and features long time overload and instantaneous short circuit pr
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
The FD2015 model is a two-pole circuit breaker, rated for 15 A, and operates with a nominal AC voltage of 600 V and DC voltage of 250 V. It is designed for continuous duty and suitable for 3-phase applications with a frequency rating of 50/60 Hz. Attachments are made on the load side, and the unit i
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Configured for right pole mounting, this undervoltage release operates within a voltage tolerance of 0.1 at 50/60 Hz. It features stripped wire ends for lead termination and utilizes pigtail leads for easy installation. The reset method relies on voltage restoration, ensuring functionality after pow
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This accessory fits J-K frame types and is intended for right-hand mounting installation. It is built to withstand operating humidity levels of 80% and can function effectively at altitudes up to 1000 meters above sea level. The device supports a temperature range from 0°C to 40°C for both operation
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Operating under the Series C range, the FDB2015 offers a two-pole configuration and features a T186 trip type. This unit is suitable for frequencies between 50 and 60 Hz, making it adaptable for different systems. It boasts an interrupting capacity of 14 kA at 480 V and 18 kA at 240 VAC, ensuring pr
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker is configured for 3-phase systems. It operates across a frequency range of 50 to 60 Hz with an AC voltage rating up to 600 V and a DC rating of 250 V. It features load side terminals and belongs to the Frame F size, with an interrupt rating of 35 kAIC at 480 VAC and 65 kAIC at 2