11 results
Eaton Cutler-Hammer / PLCs / BW Breakers
This thermal magnetic circuit breaker has a maximum interrupting capacity of 25 kA at 240 V. It offers protection through long-time and instantaneous functions. The operating humidity can be maintained at 80% without condensation, and it is rated for installation at altitudes up to 1000 meters above
Eaton Cutler-Hammer / PLCs / BW Breakers
This two-pole main breaker is rated for a current of 200 A and has an interrupting capacity of 10 KAIC. It connects via a plug-on method. Designed for single-phase applications, the BW2200 operates effectively within a humidity range of up to 80% non-condensing and is suitable for installation at al
Eaton Cutler-Hammer / PLCs / BW Breakers
This main circuit breaker features a compact design with a two-pole configuration and is intended for installation in MHM/MHR load centers. It has a thermal-magnetic trip mechanism and a short-circuit rating of 25kA at 240V. The device is compatible with wire sizes ranging from #2 AWG up to 300 kcmi
Eaton Cutler-Hammer / PLCs / BW Breakers
This main circuit breaker features two poles and is suitable for single-phase configurations. It has an interrupt rating of 25 kA, ensuring safety during fault conditions. Designed for panel mounting, it utilizes a bolt-on connection for secure installation.
Eaton Cutler-Hammer / PLCs / BW Breakers
This circuit breaker, part of the BW Breakers series, incorporates two poles and is ideal for single-phase systems. It offers long time and instantaneous trip functions while boasting an interrupt rating of 25 kA at 120/240 VAC. Mounted easily in panels, it features a bolt-on connection for secure i
Eaton Cutler-Hammer / PLCs / BW Breakers
This circuit breaker is rated for an interrupting capacity of 10 kAIC and is compatible with wire sizes ranging from #2 AWG to 300 kcmil, including both copper and aluminum types. Designed for use with ECB unit enclosures, it employs a plug-in connection method and adheres to UL certification standa
Eaton Cutler-Hammer / PLCs / BW Breakers
Designed with a thermal magnetic trip mechanism, the BW2225 protects circuits against overload and short circuit conditions. With an interrupt rating of 10 kA, it can handle considerable fault currents. The device accommodates wire sizes ranging from 2 AWG to 300 kcmil and has plug-on connection cap
Eaton Cutler-Hammer / PLCs / BW Breakers
Designed as a two-pole breaker, the BW2175 has a current rating of 175 Amperes and an interrupting capacity of 10 kA. It is suitable for main breaker mounting and accommodates a wire size range from 2 AWG to 300 kcmil. The device is rated for a maximum temperature of 60 degrees Celsius and holds UL
Eaton Cutler-Hammer / PLCs / BW Breakers
This circuit breaker features two poles and supports a common trip function. It has an interrupt rating of 25 kAIC, enhancing its capability to manage electrical faults. The BWH2225 uses a line-side terminal connection for installation and is mounted using a bolt-on method.
Eaton Cutler-Hammer / PLCs / BW Breakers
This two-pole circuit breaker features a thermal-magnetic trip type, ensuring reliable protection against overload conditions. It has an interrupting capacity of 25 kAIC and operates efficiently at frequencies between 50 and 60 Hz. The unit connects to the panel using plug-on terminal types and supp