Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker consists of three poles and features a T186 trip type. It has an interrupting capacity of 18 kAIC at 240 V AC and 14 kAIC at 480 V AC. Applicable for frequencies between 50 and 60 Hz, this breaker is suited for various electrical applications.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
With a frequency rating of 50/60 Hz, the CHLD3600F's rugged build allows for a voltage rating of 600 Vac and 250 Vdc. The breaker supports multiple trip functions including long-time and instantaneous, enhancing its adaptability for various circuit protections. The unit achieves a notable interrupt
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This unit operates efficiently within a temperature range of 0°C to 40°C, with the same limits applied for storage conditions. It can function optimally under a maximum humidity of 80% without condensation. The device is suited for installation at altitudes not exceeding 1000 meters above sea level.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Designed for robust applications, the EHD2030 features an frame type and includes a UL certification for quality assurance. It provides an interrupting capacity of 18 kAIC at 240V and 14 kAIC at 480V. This unit is suitable for installations up to 1000 meters above sea level, supporting diverse opera
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This auxiliary switch features a contact configuration of 1NO + 1NC, making it versatile for various applications. It connects via pigtail leads and can be mounted on either side of compatible breaker frames, including KD, DK, KDB, KW, and KG. The unit supports operating frequencies of 50/60 Hz and
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features a single pole with a standard interrupt capacity class. With fixed thermal and magnetic trip technology, the EHD1020 effectively protects against overcurrent conditions. Terminal connections are made on the load side, and the device is designed for 50/60 Hz operation, c
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features a thermal magnetic trip unit and is housed in an F frame type. The FD1015 has an interrupt rating of 18 kA at 347 Volts AC and 35 kA at 277 Volts AC, making it suitable for managing fault conditions. It includes lugs for load side connections and a busbar for line side
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker contains three poles and features the T186 trip type. It can handle frequencies between 50 Hz and 60 Hz and is housed in an F Frame design. With impressive interrupt ratings, it can manage 200 KAIC at 240 V AC and 100 KAIC at 480 V AC.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This shunt trip device operates within a minimum DC control voltage of 220 VDC and a maximum of 250 VDC. It also supports a control voltage range from 415 VAC to 600 VAC, ensuring compatibility with various setups. This model is designed specifically for frame types FD and is compatible with FDB, HF
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This thermal-magnetic trip unit is fitted with an adjustable instantaneous trip mechanism and has a long-time thermal element calibrated for operation at 40 °C ambient temperature. It is designed for compatibility with 50/60 Hz frequency, ensuring versatile application across various systems. The un