462 results
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
With a rated voltage of 240 VAC and 125 V DC, the EDH3150 provides robust circuit protection. The device includes three poles and has an interrupt rating of 100 KAIC at 240 VAC. For use in 3-phase configurations, the circuit breaker performs optimally at altitudes up to 1000 meters, with storage hum
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
The GHB3080S1 features three poles and a G Frame construction, specified for voltage ratings of 480Y/277 VAC and 125/250 VDC. With an interrupt rating of 65 KAIC at 240 VAC and 14 KAIC at 480Y/277 VAC, it is equipped for managing faults efficiently, making it a reliable choice for demanding electric
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This rating plug is compatible with various frames, including LD, HLD, LDB, and others in the Series C lineup. It is built to function within a temperature range from 0°C to 40°C and supports both operating and storage humidity levels of 80% (non-condensing).
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Designed for compatibility with FD frame types and several others, the SNT1LP12K operates at an AC voltage rating of 208/380 Volts and a DC rating of 110/127 Volts. It utilizes pigtail leads for connections and is mounted on the left side. The device is rated for an operating humidity of 80% without
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
The EHD2060 circuit breaker operates with a frequency range of 50 to 60 Hertz. It supports 480 Volts AC or 250 Volts DC ratings, ensuring versatility in usage. This device features a fixed thermal magnetic trip unit and includes a busbar connection method on the line side, with lugs used for load si
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This unit features long-time overload thermal protection and operates within a thermal-magnetic trip mechanism. The MT3300T trip unit is designed to be mounted inside the molded case breaker frame and is compatible with the J-K frame size. Its magnetic trip range spans from 1500 A to 3000 A, ensurin
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This unit features a trip type of T186 and supports three poles, suitable for 3-phase systems. Its rated voltage is 600 VAC for AC applications, while it accommodates up to 250 VDC. The JDB3100 provides an interrupt rating of 65 KAIC at 240 V and 35 KAIC at 480 V, solidifying its safety credentials.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker rating plug is engineered for multiple frame types, including ND, HND, NDC, and others. It functions effectively within a specified temperature range from 0°C to 40°C and operates efficiently in humidity levels of up to 80%, non-condensing. Additionally, it is designed for insta
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Featuring robust safety ratings, the GHB3090S1 has an interrupt capacity of 65 kAIC at 240V and 14 kAIC at 480V. Designed for three-phase systems, this breaker connects via a left pigtail and is suitable for both 50 and 60 Hz frequencies. Additionally, it includes a 120 V shunt trip option and is in
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Featuring three poles, the SNT4LP26K integrates seamlessly with molded case circuit breaker controls. It employs pigtail lead connections and is designed for left-side mounting. This shunt trip accessory has received UL approval, ensuring compliance with industry safety standards.