Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features both fixed thermal and fixed magnetic trip types, allowing for long-time and instantaneous trip functions that enhance protection. It has an interrupting capacity of 65 kAIC at 240 VAC and 22 kAIC at 480 VAC, ensuring safety in various applications. Additionally, it off
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
The FD3025 circuit breaker features three poles and operates with fixed thermal and magnetic trip types. It provides high interrupting ratings of 65 kAIC at 240 VAC and 35 kAIC at 480 VAC, suitable for various applications with frequencies between 50 Hz and 60 Hz.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This electronic circuit breaker operates with three poles and has a minimum frequency of 50 Hz and a maximum frequency of 60 Hz. The interrupt ratings are rated at 35 KAIC for 480 V AC and 65 KAIC for 240 V AC, providing significant fault current protection.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Part of the Series C circuit breakers, this model features an instantaneous trip unit and a magnetic trip range between 1000 and 2000 Amperes. With a notable interrupt rating of 35 kA at 480 V, it provides solid protection for electrical systems.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Constructed for three-phase systems, this circuit breaker comprises three poles and utilizes fixed thermal and fixed magnetic trip types. It offers long-time and instantaneous tripping functions to protect against overloads and short circuits. The LDC3600 has an interrupt rating of 200 kAIC at 240 V
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features three poles and is compatible with both AC and DC applications, supporting 600 VAC and 250 VDC respectively. It offers panel mounting through a bolt-on method and comes equipped with buss bar connections for the line side and lugs for the load side. Its interrupting cap
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Designed for compatibility with FD frame types and several others, the SNT1LP12K operates at an AC voltage rating of 208/380 Volts and a DC rating of 110/127 Volts. It utilizes pigtail leads for connections and is mounted on the left side. The device is rated for an operating humidity of 80% without
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features a three-pole configuration with an ampacity of 80 Amperes. It operates effectively within a frequency range of 50 to 60 Hertz. The device has an interrupt rating of 100 kiloamperes at 240 Volts AC, 65 kiloamperes at 480 Volts AC, and 25 kiloamperes at 600 Volts AC, maki
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker comes with dual poles and features a fixed thermal and magnetic trip type. It has a high interrupting capacity of 200 kAIC at 240 VAC and 100 kAIC at 480 VAC, along with a 35 kAIC rating at 600V AC. The mounting design is intended for bolt-on configurations, ideal for secure ins
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
The EDH3200 has a three-pole configuration and features both fixed thermal and fixed magnetic trip types. Offering an interrupting capacity of 100 kAIC at 240 VAC, it provides robust protection. This breaker is designed for operation within a frequency range of 50 Hz to 60 Hz and includes load side