507 results
Schneider Electric / PowerPact
This P-frame molded case circuit breaker features a solid state design with electronic trip capabilities. It can accommodate three phases and is compliant with UL and CSA standards. The breaker is rated for 100 kA at 240V, 65 kA at 480V, and 25 kA at 600V, ensuring substantial interruption capabilit
Schneider Electric / PowerPact
This device has three poles and is rated at 100% capacity. Interrupt ratings include 100kA at 240V, 65kA at 480V, and 25kA at 600V. It uses solid-state technology for operation, with lugs for load-side terminations. The actuator is a toggle design, and the trip unit is identified as Micrologic 5.0A.
Schneider Electric / PowerPact
Designed with a breaking capacity of 10 kA and a breaking capacity code designated as B, this circuit breaker is suited for standard operational voltages up to 240 V. The device can function effectively within frequencies ranging from 50 Hz to 60 Hz, and supports a rated impulse withstand voltage of
Schneider Electric / PowerPact
This circuit breaker operates at a rated voltage of 240 volts and can handle breaking capacities of 25 kA. It is capable of functioning within a frequency range between 50 Hz and 60 Hz. The unit's rated impulse withstand voltage is 8 kV, making it suitable for various applications.
Schneider Electric / PowerPact
This circuit breaker operates at a rated voltage of 240 V AC and offers breaking capacity of 25 kA under code D ratings. It functions within 50/60 Hz frequencies and ensures an impulse withstand voltage of 8 kV. Continuous current rating is set at 80%, while magnetic tripping occurs at 1800 A, with
Schneider Electric / PowerPact
This circuit breaker offers a significant interrupting capacity of 65 kA and follows the G breaking capacity code. It utilizes a thermal-magnetic trip unit, which allows it to handle magnetic hold currents up to 1200 A and trip at 2400 A. The continuous current capacity is rated at 80%, allowing for
Schneider Electric / PowerPact
This circuit breaker features an operating handle for control and is rated HACR compliant. It is designed for busbar connections and has a tightening torque of 68 N.m. With a weight of 23.6 kg, this device operates effectively within an ambient temperature range from -25°C to 70°C and is protected a
Schneider Electric / PowerPact
The JLP36200 features a three-pole design and employs a thermal magnetic trip unit for effective fault protection. It offers long-time and instantaneous functions, with interrupting ratings of 125 kA at 240V AC, 100 kA at 480V AC, and 50 kA at 600V AC. This circuit breaker is mounted as a unit and u
Schneider Electric / PowerPact
With three poles, this trip unit has an impressive short circuit breaking capacity reaching 80%. Built to comply with UL standards, it ensures reliable performance with a tightening torque of 8 lbf.in. The unit’s protection class of IP20 and NEMA 1 enclosure rating reinforce its suitability for indo
Schneider Electric / PowerPact
The QGL32175 features a thermal-magnetic trip unit that provides accurate overload and short-circuit protection. With an interrupting capacity of 65 kA at 240 V AC and a breaking capacity code of G, this device is designed to securely manage faults. Mounting is facilitated with unit lugs on both end