714 results
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This molded case circuit breaker trip unit has a frame size designated as Frame K and operates with a trip type T266. Designed for medium to high humidity environments, it maintains functionality in conditions up to 80% humidity. Temperature ranges for both operation and storage extend from 0°C to 4
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This three-pole circuit breaker features a T186 trip type and is housed in a frame designated as Frame J. It can handle an interrupt rating of 65 kAIC at 240 Vac and 35 kAIC at 480 Vac. Weighing 9.25 lbs, this unit utilizes aluminum for its terminals and supports wire sizes ranging from 4 AWG to 350
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker trip unit applies to three-pole configurations, designed for utilization in a J frame. It features a fixed thermal and adjustable magnetic trip type with a magnetic trip range of 350 to 700 A. Operational frequency ranges from 50 Hz to 60 Hz, making it adaptable to different sys
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Operating within a fixed thermal and magnetic trip type, the EHD3080 has a frame designation of F. It includes a load-side terminal configuration, and offers an interrupting capacity of 18 kAIC at 240 volts and 14 kAIC at 480 volts. This device is UL certified and functions optimally within an ambie
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Designed with two poles, the EHD2090 features a trip type of T186. It has interrupt capabilities rated at 18 KAIC for 240 VAC and 14 KAIC for 480 VAC. The frame type is designated as F Frame, and it functions across a frequency range of 50 Hz to 60 Hz.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker is equipped with fixed thermal and magnetic trip mechanisms to offer consistent protection. Its interrupting capacities are rated at 65 kAIC for 240 VAC and 22 kAIC for 480 VAC. The frequency range it operates in is between 50 to 60 Hz, making it adaptable for various applicatio
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This switch comes with three poles and a K Frame type designation, allowing for versatile installations. It features high instantaneous magnetic override for self-protection and maintains a maximum interrupting capacity of 65 kA at 240 Volts and 35 kA at 480 Volts. The operating temperature range is
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker is part of the Series C lineup and utilizes the T186 trip type for effective operation. The product is well-suited for both high and low voltage applications with substantial interrupting capacities of 65 kAIC at 240 Vac and 35 kAIC at 480 Vac. It is designed for panel mounting
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker operates with a nominal voltage ranging from 125 to 250 Volts DC and 277 to 480 Volts AC. It is rated for an interrupt capacity of 65 kA at 240 Volts AC and 14 kA at higher voltages. The GHB2050 features a G frame design with two poles and operates at frequency ratings of 50 to
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This three-pole circuit breaker adheres to a temperature rating of 40 °C and is compatible with a wire size ranging from 4 AWG to 350 kcmil for both aluminum and copper conductors. It features a robust interrupt rating of 100 kAIC for 240 VAC systems and 65 kAIC for 480 VAC configurations, ensuring