Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker contains two poles and operates within a single-phase system. It features interrupting ratings of 18 kAIC at 240V AC and 14 kAIC at both 480V AC and 600V AC. Designed for a frequency rating of 50/60 Hz, this breaker uses a bolt-on mounting connection with load side lugs for term
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This trip unit features three poles and is designed for compatibility with MDL, HMDL, CMDL, and CHMDL frame types. It incorporates advanced Digitrip 310 RMS technology. The LSG trip functions include long-time, short-time, and ground fault protections, ensuring reliable operation and safety across a
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This unit includes three poles and is rated for 50/60 Hz operation. It utilizes aluminum for terminal construction and has a T186 trip type. The circuit breaker can manage wire sizes between 250 and 500 kcmil for copper or aluminum conductors, with an interrupt rating of 35 kAIC at 480 VAC and 65 kA
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Engineered with a three-pole configuration, this circuit protector is compatible with 3-phase systems. The magnetic trip range spans from 9 A to 30 A, providing flexible operation in various applications. With an interrupting rating of 65 kAIC at 480 VAC, this unit ensures reliable fault interruptio
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Designed with a J-K frame, the HMCP050K2C features a magnetic trip range between 50 and 500 amperes. It operates within a voltage capacity of 600 volts AC and 250 volts DC. This circuit protector provides an interrupting capacity of 65 kA for AC applications at 480 volts and 22 kA for DC application
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This motor circuit protector accommodates three poles and has a frame size classified as J-K. It operates within a magnetic trip range of 350 to 700 Amps. The device is compliant with NEMA 5 starter size and functions effectively at frequencies of 50 or 60 Hz, even in relative humidity levels up to
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This trip unit features three poles and operates under thermal magnetic trip technology that is non-interchangeable. It is rated for operation at altitudes up to 2000 meters and is designed to function within an operating temperature range of –25 °C to +70 °C. With a relative humidity tolerance of 9
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This undervoltage release mechanism facilitates right-hand mounting and features pigtail leads for easy installation. Its operational temperature ranges from 0°C to 40°C, while it effectively maintains performance in humidity levels of up to 80% (non-condensing). It can be installed effectively at a
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This device, featuring two poles, utilizes a T186 trip type and is designed for use in various frequency settings, with a minimum frequency of 50 Hz and a maximum of 60 Hz. At an interrupt rating of 35 kAIC at 480 VAC and 65 kAIC at 240 VAC, it provides robust protection for electrical circuits.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
With support for operation at voltages of 480Y/277 VAC and 125/250 VDC, the GHB2060 is well-suited for various electrical systems. The unit has a fixed thermal and magnetic trip type and operates effectively within a frequency range of 50 to 60 Hertz. Its interrupt rating is 14 kAIC at 480Y/277 VAC