Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This device features three poles and is built on a G frame. The circuit breaker can handle an interrupt capacity of 65 kiloamperes at 240 Volts AC and 22 kiloamperes at 480 Volts AC. It incorporates thermal magnetic trip technology and has UL certification for safety and compliance.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
The GD3100 features a G frame size and has three poles. It is designed for a minimum frequency of 50 Hz and a maximum frequency of 60 Hz. Its interrupting capabilities reach 65 KAIC at 240 V AC and 22 KAIC at 480 V AC, ensuring it can manage significant fault currents. Additionally, it supports rate
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features a 2-pole design and supports a frequency range from 50 Hz to 60 Hz. It operates effectively at a rated current of 100 A with an interrupt rating of 42 KAIC at 240 VAC. The breaker is constructed for load side terminals, making it suitable for various installation types.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Designed with fixed thermal and magnetic trip functions, this breaker operates efficiently within a frequency range of 50 to 60 Hz. It features a 100% rating and is constructed with three poles for robust circuit management. The connection type is bolt-on, suitable for easy installation, and it meet
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker trip unit operates within a voltage rating of 600 VAC and includes a fixed trip type labeled T185. It is designed for 3-phase systems and effectively handles frequencies from 50 to 60 Hz. Rated for an ambient temperature of up to 40 °C, it provides both long-time thermal and ins
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This unit features three poles and operates under a thermal-magnetic trip mechanism, known as the TI85 type. It supports installation at altitudes up to 1000 meters above sea level and is designed to function within specific temperature limits of 0°C to 40°C for both operation and storage.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Designed for three-pole configurations, the EDH3100 features a thermal magnetic trip unit that supports both long-time and instantaneous protection functions. It utilizes lugs for load side connections and accommodates busbar connections on the line side. The device has an impressive interrupting ra
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
The trip unit features three poles and includes long-time and instantaneous tripping functions (LI). With a frequency rating between 50 and 60 Hertz, this thermal magnetic trip unit is compliant with UL standards and is compatible with multiple circuit breaker frames, including CKD and KD.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker is equipped with a fixed thermal and fixed magnetic trip unit. It features a connection type of bolt-on and can handle a DC voltage of 250 V. With an interrupt rating of 100 kA at 240 V and 65 kA at 480 V, it provides substantial protection against overcurrent conditions. The un
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker operates with a rated current of 15 A, suitable for various applications. It has an interrupting capacity of 14 kA at 480 V and 18 kA at 240 V. Supporting frequencies of 50 to 60 Hz, this breaker is specifically designed with load side terminals.