462 results
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Designed for right-side mounting, this fixed shunt trip is suitable for L and F frame sizes. It features three poles and has a connection method using pigtail leads. The installation altitude is capped at 1000 meters above sea level, ensuring compatibility with various industrial settings.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This model belongs to the Series C Circuit Breakers and has a J-K frame size. It can handle a rated voltage of 600 V AC and 250 V DC. The T266 trip type ensures reliable circuit protection. It is designed for operation within a temperature range of 0°C to 40°C, also relevant for storage conditions.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features two poles and utilizes a fixed thermal-magnetic trip unit for effective overload protection. It has an interrupting capacity of 14 kAIC at 480Y/277VAC and 65 kAIC at 240V AC. The mounting method is bolt-on, making it easy to install. Additionally, connections on the lin
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker operates within a frequency range of 50 to 60 Hz and supports 3-phase configurations. It is rated for an AC voltage of 480Y/277 VAC and a DC voltage of 125 to 250 VDC. Additionally, the G Frame size ensures compatibility with existing installations while being able to function i
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This three-pole circuit breaker features a thermal magnetic trip unit, providing protection against long-time overloads as well as instantaneous short circuits. It has an impressive interrupt rating of 100 kA at 240 Volts AC, and its maximum operating temperature range is from -20 to 70 degrees Cels
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features a thermal magnetic trip unit and is housed in an F frame type. The FD1015 has an interrupt rating of 18 kA at 347 Volts AC and 35 kA at 277 Volts AC, making it suitable for managing fault conditions. It includes lugs for load side connections and a busbar for line side
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Rated to interrupt up to 35 kiloamperes at 277 Volts AC, this circuit breaker ensures protection in demanding scenarios. It is suited for panel or DIN rail mounting, providing versatile installation options. The FD1030 includes a thermal magnetic trip unit and has a single pole configuration.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker operates at a maximum AC voltage of 600 VAC with a feed-thru connection type. It features a K-frame design and is capable of providing magnetic-only protection. Additionally, it has a 35 kA AIC rating at 480 V, ensuring protection against fault currents. It is also suitable for
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This thermal-magnetic trip unit is fitted with an adjustable instantaneous trip mechanism and has a long-time thermal element calibrated for operation at 40 °C ambient temperature. It is designed for compatibility with 50/60 Hz frequency, ensuring versatile application across various systems. The un
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features two poles and is designed to handle frequencies between 50 Hz and 60 Hz. Its interrupt rating at 240 VAC is 100 KAIC, while at 480 VAC, the rating is 65 KAIC. The HFD2110 includes a load-side terminal type for efficient connection.