404 results
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features three poles for three-phase systems, housed in a K frame. With a thermal magnetic trip unit, it provides reliable long-time overload and instantaneous short-circuit protection. This model is also certified by UL and CSA, with a range of interrupt ratings for different v
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Featuring a compact F frame design, this device includes two poles and is rated for an impressive 150 Amps. It accommodates a frequency range between 50 Hz and 60 Hz. The circuit breaker is equipped with high interrupting capabilities, rated at 100 KAIC for 240 VAC and 65 KAIC for 480 VAC, ensuring
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This GHB circuit breaker operates efficiently with a voltage rating of 480Y/277 volts AC and 125/250 volts DC. It is rated for 50/60 hertz operation and delivers an interrupt rating of 14 kAIC at 480Y/277 V AC and 65 kAIC at 240 V AC. It accommodates wire sizes from AWG #10 to 1/0 for both copper an
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit protector features three poles and utilizes magnetic trip technology exclusively. It is intended for bolt-on mounting and has connections for both line and load using lugs. Compatible with 50/60 Hz frequency ratings, it meets UL and CE approval standards.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features a T186 trip type, combining fixed thermal and magnetic functions. It is configured with three poles and facilitates a line and load terminal arrangement, using aluminum for terminal construction. The J frame design supports frequency ratings from 50 Hz to 60 Hz, and it
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This three-pole accessory is compatible with 3-phase systems and features voltage ratings of 110–125 VDC and 110–240 VAC. The shunt trip is electrically actuated and mounts to the left or right, making it versatile for applications involving breaker control. It connects via pigtail leads and utilize
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker comprises a single pole and utilizes a fixed thermal-magnetic trip unit for effective overload protection. It offers an impressive interrupting capacity of 18 kA at 240 volts AC and 14 kA at 480 volts AC.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
With a J-K frame size, this motor circuit protector operates at a rated voltage of 600 V for AC and 250 V for DC. The magnetic trip range extends from 300 A to 1000 A. It has impressive interrupting ratings: 65 kA at 480 VAC, 25 kA at 600 VAC, and 42 kA at 250 VDC. The device is bolted for secure mo
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker contains two poles and operates within a single-phase system. It features interrupting ratings of 18 kAIC at 240V AC and 14 kAIC at both 480V AC and 600V AC. Designed for a frequency rating of 50/60 Hz, this breaker uses a bolt-on mounting connection with load side lugs for term
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features a single pole with a standard interrupt capacity class. With fixed thermal and magnetic trip technology, the EHD1020 effectively protects against overcurrent conditions. Terminal connections are made on the load side, and the device is designed for 50/60 Hz operation, c