462 results
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This three-pole breaker supports a fixed thermal and magnetic trip unit, providing instantaneous trip functionality through fixed magnetic means. Its input specs include 250 VDC and is rated for a frequency range of 50 to 60 Hz. The KD3400F device is designed for bolt-on mounting and has an interrup
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
The HKD3400W is designed to support a 3-phase system and features a total of three poles. It utilizes a fixed thermal-magnetic trip unit and offers a frequency rating of 50/60 Hz. Its interrupting capability is rated at 100 kAIC for 240V AC and 65 kAIC for 480V AC. Terminal connections are accomplis
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker operates at a voltage of 480Y/277 VAC and 125/250 VDC. The GHB3025 model employs fixed thermal and magnetic trip mechanisms for reliable trip action. It has a maximum interrupting capacity of 65 kAIC at 240V and 14 kAIC at 480Y/277V, making it suitable for high-demand applicatio
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
The LD3600F features an L frame type and is designed with three poles, allowing for efficient circuit management. It supports a frequency range from 50 Hz to 60 Hz, with an interrupt capacity of 35 kAIC at 480 VAC and 65 kAIC at 240 VAC. Thermal magnetic protection ensures reliable operation by safe
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This three-pole circuit breaker features a T-frame design and supports a bolt-on connection style. Rated to interrupt at a capacity of 65 kA at AC voltage levels of 600 volts, it utilizes a magnetic trip function, omitting thermal elements. It is compliant with UL 489 standards and operates efficien
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features a fixed thermal-magnetic trip unit, managing both long-time and instantaneous trip functions. It includes a robust interrupt rating of 65 kA for AC use and 10 kA for DC, adequately securing electrical systems against faults. Configured with three poles, it employs stand
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This trip unit operates within a frequency range of 50 to 60 Hertz and features non-interchangeable trip settings. The LT3300T is fitted for use with 3-pole circuit breakers and is constructed with a thermal magnetic trip unit. It can handle a maximum current rating of 2,500 amperes.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Eaton's HMCP050G2C is a circuit breaker that provides instantaneous trip functions and is specifically intended for motor protection. It supports an operating frequency of 50/60 Hz and is equipped with feed-thru connections. Designed to handle a maximum DC voltage of 250 VDC, this breaker ensures re
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This three-pole breaker features a trip type of T186 and adheres to substantial interruption ratings: 14 kAIC at 480Y/277 V AC and 65 kAIC at 240 V AC. It accommodates a wire range between AWG #10 to 1/0, suitable for both aluminum and copper conductors.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Compatible specifically with K Frame HMCP Circuit Breakers, the SNT3P14K features a current rating of 400 A and is designed for three poles. The interrupt rating of this trip device aligns with that of the compatible breaker frame, ensuring safe operations. It is suitable for multiple frame types, i