714 results
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This 3-pole DK Breaker is housed in a K-frame and includes a fixed thermal and fixed magnetic trip technology. It is rated for AC interrupting capacity of 65 kAIC at 240 VAC and DC interrupting capacity of 10 kAIC at 250 VDC. The unit weighs 11.5 lbs and is configured as a complete breaker, accommod
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker operates effectively at voltages of 480Y/277 V AC and 125/250 V DC. Additionally, it's rated for a frequency of 50/60 Hz. With an interrupt capacity of 14 kAIC at 480Y/277 Volts AC and up to 65 kAIC at 240 V AC, it ensures reliable protection. The unit is UL Listed, confirming s
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Constructed from aluminum, this line and load terminal kit features two barrels and is intended for use in 3-phase applications. Rated for 600 volts AC, it accommodates wire sizes ranging from 400 to 500 thousand circular mils. The device complies with relevant safety standards, being UL-certified,
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This device is a molded case breaker trip unit with three poles and a frame size categorized as J-K. It features an operating voltage rating of 600 VAC and is rated for a current of 300 A. The non-interchangeable thermal magnetic trip function is designed for long-time and instantaneous performance,
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This particular model operates effectively within a frequency range of 50 to 60 Hz and features a G frame size. The GHB2030 is a two-pole circuit breaker, providing reliable protection with an interrupt rating of 14 KAIC at 480Y/277 VAC and 65 KAIC at 240 VAC. It can be installed at altitudes up to
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
The HJD3250 model features a J-frame design and includes three poles for three-phase systems. Interrupting capacities are rated at 100 KAIC for 240 VAC and 65 KAIC for 480 VAC. It uses fixed thermal and magnetic trip type mechanisms for added reliability.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Part number GHB3050 belongs to the Series C Circuit Breakers, offering a robust protection solution with a mounting style designed for bolt-on installation. Rated for both AC and DC voltages, it features interrupting capacities of up to 65 kAIC at 240 VAC and 14 kAIC at 480 VAC, accommodating divers
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This three-pole circuit breaker features a T-frame design and supports a bolt-on connection style. Rated to interrupt at a capacity of 65 kA at AC voltage levels of 600 volts, it utilizes a magnetic trip function, omitting thermal elements. It is compliant with UL 489 standards and operates efficien
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
The trip unit features three poles and includes long-time and instantaneous tripping functions (LI). With a frequency rating between 50 and 60 Hertz, this thermal magnetic trip unit is compliant with UL standards and is compatible with multiple circuit breaker frames, including CKD and KD.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
With three poles, the EDH3100 is built for use in 3-phase systems. It features thermal magnetic tripping, accommodating both long-time and instantaneous functions (LI). Designed for operations at frequencies from 50 Hz to 60 Hz, this circuit breaker has an interrupting rating of 100 kAIC at 240 VAC