507 results
Schneider Electric / PowerPact
Designed for excellence in electrical protection, this circuit breaker utilizes an operating handle for manual control. With a significant breaking capacity and impulse withstand voltage of 8 kV, it provides reliable circuit interruption. The magnetic tripping current is set at 2400 A, and the hold
Schneider Electric / PowerPact
This circuit breaker operates at a rated voltage of 240 V AC and offers breaking capacity of 25 kA under code D ratings. It functions within 50/60 Hz frequencies and ensures an impulse withstand voltage of 8 kV. Continuous current rating is set at 80%, while magnetic tripping occurs at 1800 A, with
Schneider Electric / PowerPact
The QGL32175 features a thermal-magnetic trip unit that provides accurate overload and short-circuit protection. With an interrupting capacity of 65 kA at 240 V AC and a breaking capacity code of G, this device is designed to securely manage faults. Mounting is facilitated with unit lugs on both end
Schneider Electric / PowerPact
This trip unit is mounted on a J-frame breaker and operates at a voltage rating of 600 VAC. It consists of three poles with a service capacity rated at 0.8. The device is compliant with UL 489 and accommodates frequency specifications of 50/60 Hz. With a height of 4 inches and a length of 4.7 inches
Schneider Electric / PowerPact
This trip unit features a thermal-magnetic trip mechanism within a J-frame molded case breaker type. It is designed to accommodate three poles and operates at 50/60 Hz. The unit complies with UL standards and has dimensions of 4.5 inches in length and 3 inches in height.
Schneider Electric / PowerPact
This P-frame molded case circuit breaker features a solid state design with electronic trip capabilities. It can accommodate three phases and is compliant with UL and CSA standards. The breaker is rated for 100 kA at 240V, 65 kA at 480V, and 25 kA at 600V, ensuring substantial interruption capabilit
Schneider Electric / PowerPact
Designed with a breaking capacity of 10 kA and a breaking capacity code designated as B, this circuit breaker is suited for standard operational voltages up to 240 V. The device can function effectively within frequencies ranging from 50 Hz to 60 Hz, and supports a rated impulse withstand voltage of
Schneider Electric / PowerPact
Designed for operational efficiency, the QDA32175 model supports a rated voltage of 240 V and a breaking capacity of 25 kA. It functions effectively in a frequency range between 50 Hz and 60 Hz. The magnetic tripping current is set at 1800 A, with a magnetic hold current of 1000 A, supporting a cont
Schneider Electric / PowerPact
This circuit breaker operates with a line rated current of 100 A and contains 2 poles. It features thermal magnetic trip technology, with a magnetic tripping current of 2400 A and a magnetic hold current of 1200 A. The component has a rated operational voltage of 240 V AC and a breaking capacity of