Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This device features a thermal-magnetic trip mechanism that includes both long-time and instantaneous trip functions. It boasts an interrupt rating of 100 kAIC at 240 VAC, 65 kAIC at 480 VAC, and 35 kAIC at 600 VAC. Additionally, the breaker has a 25 kAIC interrupt rating for 250 VDC applications.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Built within the Series C line, this circuit breaker features three poles and incorporates both fixed thermal and fixed magnetic trip types. The KG3400 has an interrupting capacity of 18 kAIC at 240 VAC and 14 kAIC at 480 VAC, ensuring dependable performance against fault conditions.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Specializing in electrical protection, this unit is compatible with multiple frame types within the Series C lineup. Featuring long-time, short-time, and ground fault trip functions, it enhances safety across various applications. With a solid-state electronic protection type and a mounting type tha
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
In the Series C line, the HFD2200 offers a robust solution with fixed thermal and magnetic trip options. This 2-pole breaker features an interrupting capacity of 100 kAIC at 240 VAC and 65 kAIC at 480 VAC. It is effective within a frequency range of 50 to 60 Hz, making it adaptable for different ele
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features three poles and is designed for three-phase applications. It employs fixed thermal-magnetic trip technology, with functions for both long-time and instantaneous trip settings. With an interrupt capacity of 100 kAIC at 240 VAC, it adheres to frequency ratings of 50–60 Hz
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker is part of the Series C lineup and is characterized by its F-frame size and complete breaker design. It accommodates three poles for versatile applications and is rated for voltage levels up to 600 volts AC and 250 volts DC. The fixed thermal trip setting and thermal-magnetic te
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This model features a robust F-frame design and includes three poles for effective distribution in three-phase applications. The thermal-magnetic trip technology provides both fixed thermal and magnetic protection for safe system operation. The unit has an interrupting capacity of 100 kA at 240 V AC
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This unit includes three poles and exhibits a robust frame type classified as F-frame. The HFD3030V also supports a frequency range between 50 and 60 Hz for versatile applications. With fixed thermal and magnetic trip technology, it ensures reliable protection. It has an interrupting capacity of 100
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
With a capacity for handling currents of 50 A, the HFD3050L circuit breaker operates efficiently, boasting a fixed thermal and magnetic trip type. It achieves an interrupting rating of 100 kAIC at 240 VAC and 65 kAIC at 480 VAC, ensuring safety in demanding environments. This unit is tailored for th
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This trip unit is rated for two poles and operates efficiently within a frequency range of 50 to 60 Hz. Its insulation voltage is rated at 600 VAC with a withstand voltage of 8 kV. It is built to perform in environments with up to 95% humidity and is suited for altitudes of up to 2000 meters.