714 results
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features an F frame size with three poles. It supports voltage ratings of up to 480 VAC for AC applications and 250 VDC for DC applications. With an interrupting capacity of 18 kAIC at 240 VAC and 14 kAIC at 480 VAC, this breaker ensures effective protection against fault condit
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker supports an AC voltage rating of 600 VAC and a DC voltage rating of 250 VDC. Its interrupting ratings are 18 kAIC at 240 VAC and 14 kAIC at 480 VAC, ensuring robust protection against surges. The trip unit is designed with fixed thermal and magnetic functions for both long-time
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker can manage AC voltages up to 600 V and DC voltages reaching 250 V. It provides solid interrupt ratings of 65 kAIC at 240 V and 35 kAIC at 480 V. The KD3400KX15Y18 employs a reliable trip configuration featuring fixed thermal and fixed magnetic options, making it suitable for a v
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker is designed for applications requiring a three-pole configuration. It has a minimum operational frequency of 50 Hz and maximum of 60 Hz. With significant interrupting capacities, it can handle 85 kAIC at 240 VAC, 50 kAIC at 480 VAC, and 25 kAIC at 600 VAC. The device features LS
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Catering to various industrial needs, the LDC3400 circuit breaker accommodates three poles and supports a voltage rating of 600 VAC and 250 VDC. Its interruption capabilities range from 200 kAIC at 240 VAC to 22 kAIC at 250 VDC, suited for critical electrical safety measures while enabling long-time
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker has an interrupt capacity of 65 kAIC when operating at 480 Vac, ensuring effective fault protection. The device can manage an operating voltage of up to 600 Vac while supporting a continuous rating of 100%. Its trip function utilizes the T165 electronic LI model for efficient ci
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker has three poles and supports installation via panel mounting. It operates efficiently at a maximum system voltage of 600 Vac with an interrupt capacity of 100 kAIC at 240V and 65 kAIC at 480V. It complies with both 50 Hz and 60 Hz frequency requirements and is designed to facili
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Designed for use in demanding environments, this circuit breaker has an AC voltage rating of 600 VAC and a rated DC voltage of 250 VDC. It incorporates an interchangeable thermal-magnetic trip unit and offers a breaking capacity of 42 kAIC at 600 VAC. The breaker is mounted in a panel style, support
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker is rated for a current of 160 A and features three poles, facilitating three-phase applications. The protection mechanism employs the Electronic Digitrip RMS 310 type, which offers long-time and short-time protection settings as part of its trip functions. With line and load ter
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This molded case circuit breaker is categorized as an F-frame device and features a fixed thermal and magnetic trip type. Its interrupting capacity is rated at 42 kAIC at 600 VAC, ensuring effective interruption in fault conditions. It operates within a frequency range of 50 Hz to 60 Hz and is suita