This miniature circuit breaker is rated for a maximum current of 6 A and responds according to Trip Curve C specifications. The device functions effectively within a frequency range of 50 Hz to 60 Hz and withstands impulse voltages of up to 4 kV. Designed for DIN rail mounting, it requires a tighten
Allen Bradley / Motors / Bulletin 1489
This single-pole miniature circuit breaker has a trip type defined as D-curve. It operates effectively with an ambient temperature range of -25°C to 55°C. The unit supports voltages up to 250 Volts AC (phase to ground) and 440 Volts AC (phase to phase). It guarantees electrical endurance for up to 2
Allen Bradley / Motors / Bulletin 1489
This thermal-magnetic circuit breaker operates efficiently with three poles and features a Trip Curve D. It handles frequencies ranging from 50 Hz to 60 Hz, ensuring compatibility with various electrical systems. The device functions within temperatures from -25°C to 55°C and supports storage temper
Allen Bradley / Motors / Bulletin 1489
This miniature circuit breaker includes a trip curve classified as Curve C, ensuring reliable tripping characteristics. It has an operating voltage range up to a maximum of 440V, making it versatile for various applications. The device can function at minimum and maximum frequencies of 50 Hz and 60
Allen Bradley / Motors / Bulletin 1489
This circuit breaker operates on a nominal voltage of 400 VAC and conforms to a trip curve type D. Its effective frequency range is between 50 Hz and 60 Hz. The unit can endure an impulse withstand test voltage of 4 kV and has a dielectric strength rating of 2 kV. Additionally, it requires a tighten
Allen Bradley / Motors / Bulletin 1489
Designed within the Bulletin 1489 series, this miniature circuit breaker operates across a frequency range of 50 to 60 Hz. It supports a short-circuit breaking capacity of 15 kA and is rated to withstand impulse voltages up to 4 kV. Furthermore, with an IP40 rating, it is designed for environments w
Allen Bradley / Motors / Bulletin 1489
This supplementary protector features a 2 pole configuration and a trip curve type designated as C. It can handle frequencies from 50 Hz to 60 Hz. Designed to interrupt short-circuits with a breaking capacity of 15 kA, it ensures reliable operation under fault conditions. The device has a dielectric
Allen Bradley / Motors / Bulletin 1489
This circuit breaker features a single-pole configuration and operates with a current rating of 1A. It is characterized by a Trip Curve C, suitable for various applications. The device can function in operating temperatures ranging from -25°C to 55°C, with storage capabilities from -40°C to 70°C.
Allen Bradley / Motors / Bulletin 1489
This two-pole circuit breaker features a current rating of 15 Amperes and can handle rated voltages of 277/480 Volts AC and 96 Volts DC. With a D-curve trip characteristic, it has an interrupting capacity of 10 kiloamperes and meets Category III overvoltage standards. The device mounts easily onto D
Allen Bradley / Motors / Bulletin 1489
This miniature circuit breaker features a thermal-magnetic trip unit and possesses a trip curve D characteristic. It can handle short circuit capacities up to 15 kiloamperes, ensuring reliable protection. The unit is mounted on a 35 mm DIN rail, maintaining stability and compatibility in installatio