Free UPS Ground on All Parcel Orders!
+1 (919) 205-4392
140G MCB

Allen Bradley 140G MCB

The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.

Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Browse 140G MCB

Browse available units in our catalog of 140G MCB.

  • 140G-J0F4-D15 from the 140G MCB series.
    Allen Bradley

    140G-J0F4-D15

    This circuit breaker comprises four poles and has a current range of 150 A. Rated for insulation up to 1000V and impulse withstand voltage of 8 kV, it is built for reliability in challenging condition

    Available
    Call
  • 140G-J2C4-C25 from the 140G MCB series.
    Allen Bradley

    140G-J2C4-C25

    This circuit breaker incorporates a four-pole design and functions with a current rating of 25 Amps and a maximum rated current of 250 Amps. It is equipped with fixed thermal and fixed magnetic protec

    Available
    Call
  • 140G-JC6C3-C30 from the 140G MCB series.
    Allen Bradley

    140G-JC6C3-C30

    This molded case circuit breaker features a JC frame and operates with a maximum current rating of 250 Amps. It allows for a current range of 30 Amps and is built to withstand a rated insulation volta

    Available
    Call
  • 140G-KTI3-D30 from the 140G MCB series.
    Allen Bradley

    140G-KTI3-D30

    This circuit breaker operates within a current range of 300 Amps and is housed in a K frame type. It accommodates a rated insulation voltage of 1000V and can withstand impulse voltages of 8 kV. The un

    Available
    Call
  • 140G-MTI4-D80 from the 140G MCB series.
    Allen Bradley

    140G-MTI4-D80

    With a robust capacity of 800 A, this product is engineered to protect essential electrical circuits. The circuit breaker features four poles, making it suitable for three-phase applications. Rated fo

    Available
    Call
  • 140G-NS5H3-E12 from the 140G MCB series.
    Allen Bradley

    140G-NS5H3-E12

    This breaker is designed with an NS frame and offers a current range of 1200 A. It has a rated insulation voltage of 1000 volts. The impulse withstand voltage is rated at 8 kV, making it suitable for

    Available
    Call
  • 140G-J0C4-C50 from the 140G MCB series.
    Allen Bradley

    140G-J0C4-C50

    This four-pole circuit breaker operates within a current range of 50 amps and incorporates fixed thermal and magnetic protection mechanisms. It supports a rated insulation voltage of 1000 volts and wi

    Available
    Call
  • 140G-JC0H3-C60 from the 140G MCB series.
    Allen Bradley

    140G-JC0H3-C60

    This unit, featuring electronic LSI for protection, is designed with a JC frame. It accommodates a current range of 60 Amps and has a rated insulation voltage of 1000 Volts. The impulse withstand volt

    Available
    Call
  • 140G-JTF4-D17 from the 140G MCB series.
    Allen Bradley

    140G-JTF4-D17

    This circuit breaker boasts four poles and offers a current range of 170 A. The frame type is categorized as J, with a rated insulation voltage of 1000 volts. It is designed to endure impulse voltages

    Available
    Call
  • 140G-JTI3-C60 from the 140G MCB series.
    Allen Bradley

    140G-JTI3-C60

    This circuit breaker supports an insulation voltage of 1000 Volts and withstands impulse voltages of 8 kV. It features a J frame and weighs 5.51 pounds. The unit is designed for a mechanical life of 2

    Available
    Call
Showing 1,161-1,170 of 1,222 results

About 140G MCB

The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.

The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.