140G-J0C4-C70
This device utilizes a four-pole configuration and features fixed thermal and magnetic protection mechanisms. It supports a current range of 70 Amps and is rated for insulation at 1000 Volts. The impu
The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.
Browse available units in our catalog of 140G MCB.
This device utilizes a four-pole configuration and features fixed thermal and magnetic protection mechanisms. It supports a current range of 70 Amps and is rated for insulation at 1000 Volts. The impu
This circuit breaker operates with a current rating of 35 A and up to 250 A of maximum current. It also operates with an insulation voltage rating of up to 1000 V and can also withstand impulse voltag
Part number 140G-J6I4-C40 is designated as a four-pole molded case circuit breaker. It operates within a rated insulation voltage of 1000 volts and can withstand impulse voltages reaching up to 8 kV.
The 140G-M0H3-D80 belongs to the M frame type and accommodates a maximum current of 800 A. It provides a rated insulation voltage of 1000 volts and withstands impulse voltage up to 8 kV. Weighing 26.6
This molded case breaker features a rating for currents up to 600 A and operates at a rated insulation voltage of 1000 volts. It can withstand impulse voltages of 8 kV and is rated for mechanical oper
This product operates effectively within a temperature range of 0 °C to 40 °C, both during operation and while in storage. It maintains functionality in humid environments, with a maximum humidity rat
This circuit breaker has a size J frame and is engineered for 35 Amps of rated current. It is rated for up to 1000 volts of insulation voltage and withstands impulse voltages of up to 8 kV. It is buil
This circuit breaker features four poles and operates within a current range of 50 A. It is suitable for 1000V rated insulation voltage and can handle impulse withstand voltages of up to 8 kV. Weighin
With three poles and operating at a voltage of 480 V AC, this circuit breaker meets UL and IEC standards. Operating frequency ranges from 50 to 60 Hz, and it includes a bottom feed type for power supp
This circuit breaker has a current range of 25 A and operates at a rated insulation voltage of 1000 volts. It is equipped to withstand impulse voltages of 8 kV. A weight of 2.65 pounds makes it lightw
The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.
The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.