140G-K-EA1R1A
This accessory features two poles and includes one alarm contact with an additional auxiliary contact for enhanced functionality. It is compatible with frame sizes K and M, and supports inside right c
The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.
Browse available units in our catalog of 140G MCB.
This accessory features two poles and includes one alarm contact with an additional auxiliary contact for enhanced functionality. It is compatible with frame sizes K and M, and supports inside right c
This circuit breaker features three poles and operates at a rated current of 20.0 A. Designed for top feed connections, it mounts easily on standard bus bars. The control voltage required for this bre
This molded case circuit breaker features an H frame and supports ratings of 600/347 volts AC. It includes a thermal magnetic trip unit for reliable performance. Designed for mounting on a panel or DI
Operating effectively within an environment between 0 °C and 40 °C, this module supports installation at altitudes up to 1000 meters above sea level. The unit is capable of withstanding maximum humidi
This circuit breaker cover is rated with an IP40 protection standard, making it suitable for general indoor applications. It operates effectively between temperatures of 0°C and 40°C. With a storage t
Featuring a size of 2.76 inches, this terminal cover is designed for installations with temperatures ranging from 0 °C to 40 °C. It maintains performance within a maximum humidity level of 80% (non-co
This molded case circuit breaker provides fixed thermal and magnetic protection. It is capable of operating at a rated voltage of 690 V and functions effectively across a frequency range of 50 Hz to 6
This circuit breaker type is configured with three poles and can handle a rated current of 15 Amps. Its thermal-magnetic protection mechanism allows for robust functionality, and it has a rated impuls
This circuit breaker is built on an H frame platform, featuring a fixed magnetic trip and is rated for a maximum interrupt capacity of 25 kA at 480 volts. It operates effectively at voltage levels of
This circuit breaker includes three poles and supports flexible cable types. Designed for panel or DIN rail mounting, it has an interrupt rating of 25 kA. The unit's painted metal handle with a bail a
The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.
The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.