Free UPS Ground on All Orders!
+1 (919) 205-4392
140G MCB

Allen Bradley 140G MCB

The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.

Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Browse 140G MCB

Browse available units in our catalog of 140G MCB.

140G-H0F3-C80

The 140G-H0F3-C80 Molded Case Circuit Breaker has a Adjust Thermal/ Adjust Magnetic Protection Type and a 2.65 lb Weight.

Call
4.9

140G-H15C3-C20

This unit features an H-frame design with fixed thermal and magnetic protection mechanisms. The current range is set at 20 Amps, and it supports a rated insulation voltage of 1000 volts. The impulse w

Available
4.6

140G-I3C4-D16

This circuit breaker operates with four poles and features fixed thermal and magnetic protection types. It can effectively handle a thermal trip setting of 160 Amps and a magnetic trip rating of 1600

Available
4.7

140G-K6X4

The 140G-K6X4 Molded Case Circuit Breaker has a Breaker Frame Protection Type and a 9.15 lb Weight.

Call
4.3

140G-G3C3-D10

The Allen-Bradley 140G-G3C3-D10 is a molded case circuit breaker with a G frame design, accommodating up to 125 Amps. It is classified as a fixed thermal and magnetic protection type, with a thermal t

Call
4.9

140G-MTH3-D80

This molded case circuit breaker features an M frame type and operates effectively at 800 Amps. It utilizes electronic LSI for protection and is rated for impulse withstand voltages of up to 8 kV. At

Call
4.6

140G-N6K3-E12

This breaker operates with a current rating of 1200 A, delivering reliable protection with electronic LSIG mechanisms. It is rated for insulation up to 1000 volts and can withstand impulses of up to 8

Call
4.7

140G-G2C4-C25

The 140G-G2C4-C25 model functions as a molded case circuit breaker, capable of handling up to 125 amps. It features a robust interrupting rating of 25 kA and is structured with four poles. This device

Available
4.9

140G-J3F3-D10

The 140G-J3F3-D10 Molded Case Circuit Breaker has a Adjust Thermal/ Adjust Magnetic Protection Type and a 5.51 lb Weight.

Call
5.0

140G-H2C3-C25

This molded case circuit breaker is characterized by its H-frame design and operates within a current range of 25 A. It possesses a notable interrupting capacity of 25 kA, ensuring effectiveness durin

In Stock Ships Today
5.0
Showing 141-150 of 1,219 results

About 140G MCB

The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.

The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.