140G MCB

Allen Bradley 140G MCB

The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.

Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Browse 140G MCB

Browse available units in our catalog of 140G MCB.

  • 140G-H6C4-C63 from the 140G MCB series.
    Allen Bradley

    140G-H6C4-C63

    The 140G-H6C4-C63 Molded Case Circuit Breaker has a Fixed Thermal/ Fixed Magnetic Protection Type and a 3.53 lb Weight.

    From $674
    In Stock Ships Today
  • 140G-J2F3-D17 from the 140G MCB series.
    Allen Bradley

    140G-J2F3-D17

    The 140G-J2F3-D17 Molded Case Circuit Breaker has a Adjust Thermal/ Adjust Magnetic Protection Type and a 5.51 lb Weight.

    Available
    Call
  • 140G-H0F3-C80 from the 140G MCB series.
    Allen Bradley

    140G-H0F3-C80

    The 140G-H0F3-C80 Molded Case Circuit Breaker has a Adjust Thermal/ Adjust Magnetic Protection Type and a 2.65 lb Weight.

    Available
    Call
  • 140G-H2C3-C35 from the 140G MCB series.
    Allen Bradley

    140G-H2C3-C35

    The 140G-H2C3-C35 is part of the Allen Bradley 140G series, equipped with an H frame and capable of handling a maximum current of 125 Amps. This molded case circuit breaker guarantees a reliable inter

    From $318
    In Stock Ships Today
  • 140G-HTF3-C80 from the 140G MCB series.
    Allen Bradley

    140G-HTF3-C80

    The 140G-HTF3-C80 Molded Case Circuit Breaker has a Adjust Thermal/ Adjust Magnetic Protection Type and a 2.65 lb Weight.

    Available
    Call
  • 140G-N0H3-E12 from the 140G MCB series.
    Allen Bradley

    140G-N0H3-E12

    This model operates within a frame size designated as N and is rated for 1200 A in current handling. The insulation voltage rating is 1000 volts, and it comfortably withstands impulse voltages as high

    From $9,838
    Available
  • 140G-H6C3-C70 from the 140G MCB series.
    Allen Bradley

    140G-H6C3-C70

    The 140G-H6C3-C70 Molded Case Circuit Breaker has a Fixed Thermal/ Fixed Magnetic Protection Type and a 2.65 lb Weight.

    Available
    Call
  • 140G-MTH3-D80 from the 140G MCB series.
    Allen Bradley

    140G-MTH3-D80

    This molded case circuit breaker features an M frame type and operates effectively at 800 Amps. It utilizes electronic LSI for protection and is rated for impulse withstand voltages of up to 8 kV. At

    Available
    Call
  • 140G-G6E3-D16 from the 140G MCB series.
    Allen Bradley

    140G-G6E3-D16

    The 140G-G6E3-D16 molded case circuit breaker operates with adjustable thermal and fixed magnetic protection types. It supports a current range of 160 A alongside functions for thermal trip set at 160

    From $2,257
    Available
  • 140G-JC6F3-D20 from the 140G MCB series.
    Allen Bradley

    140G-JC6F3-D20

    This circuit breaker is capable of managing a current range of up to 200 A. It supports adjustable thermal and magnetic protection, enhancing its versatility. The insulation voltage rating stands at 1

    From $2,981
    In Stock Ships Today
Showing 161-170 of 1,222 results

About 140G MCB

The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.

The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.