140G-H3C4-C32
This circuit breaker features four poles and operates within a current range up to 32 Amps. It offers fixed thermal and magnetic protection types, providing enhanced safety in diverse applications. Ra
The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.
Browse available units in our catalog of 140G MCB.
This circuit breaker features four poles and operates within a current range up to 32 Amps. It offers fixed thermal and magnetic protection types, providing enhanced safety in diverse applications. Ra
This model supports a current range of 25 A and utilizes electronic LSIG protection. It operates under rated insulation voltages of 1000 V and withstands impulse voltages of up to 8 kV. Weighing 2.65
This device is designed with a J-frame and rated for current levels of 50 A. Protection is provided through fixed thermal and magnetic mechanisms. It can withstand an insulation voltage of 1000 volts
This circuit breaker operates within a J frame and includes fixed thermal and fixed magnetic protection technology. It manages 32 A of rated current and 250 A of maximum current. It is rated for 1000V
This circuit breaker features 4 poles and offers adjustable thermal and magnetic protection. It supports a current range of 160 A, with a rated insulation voltage of 1000 volts. Additionally, it withs
The 140G-J6H3-C40 functions efficiently within a current range of 40 Amps. It is rated for insulation voltage up to 1000 volts and withstands impulse voltages of 8 kV. Weighing 5.51 pounds, this unit
With an electronic LSIG protection scheme, the 140G-J6I3-D25 ensures precise monitoring of electrical currents. It has a rated insulation capability of 1000 volts and can endure impulse voltages of up
This circuit breaker operates with four poles and is designed for a current rating of 400 A. It has a rated insulation voltage of up to 1000 volts and can withstand impulse voltages of 8 kV. The unit
This breaker operates with a rated insulation voltage of 1000 Volts and an impulse withstand voltage of 8 kV. The mechanical lifespan of the 140G-JC6X3 is 240 operations per hour, while the electrical
This circuit breaker can accommodate a current range up to 160 A and is built with adjustable thermal and magnetic protection for enhanced fault management. It supports a rated insulation voltage of 1
The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.
The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.