Allen Bradley 140G MCB

The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.

Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Browse 140G MCB

Browse available units in our catalog of 140G MCB.

  • 140G-H15C3-C60 from the 140G MCB series.
    Allen Bradley

    140G-H15C3-C60

    This model belongs to the 140G series and includes fixed thermal and magnetic protection. It is rated for a current range of 60 amps and designed with a robust frame H structure. The insulation voltag

    Available
    Call
  • 140G-H15C4-C15 from the 140G MCB series.
    Allen Bradley

    140G-H15C4-C15

    This molded case circuit breaker is engineered within the 140G series, featuring an H frame design. Capable of addressing electrical systems with insulation voltage ratings of 1000 V, it withstands im

    Available
    Call
  • 140G-H15F4-D16 from the 140G MCB series.
    Allen Bradley

    140G-H15F4-D16

    This unit, categorized within the 140G MCB series, supports four poles and offers adjustable thermal and magnetic protection features. It enables operation in a current range that reaches up to 160 A.

    Available
    Call
  • 140G-H15I3-C25 from the 140G MCB series.
    Allen Bradley

    140G-H15I3-C25

    This circuit breaker has a current range of 25 Amps and is rated for a maximum insulation voltage of 1000 V. Additionally, it has a rated impulse withstand voltage of 8 kV. Weighing 2.65 pounds, it fi

    Available
    Call
  • 140G-H15I4-D10 from the 140G MCB series.
    Allen Bradley

    140G-H15I4-D10

    Part of the 140G series, the 140G-H15I4-D10 operates at a rated insulation voltage of 1000 volts and a rated impulse withstand voltage of 8 kV. It has a current range of 100 A with mechanical life rat

    Available
    Call
  • 140G-H2C4-C15 from the 140G MCB series.
    Allen Bradley

    140G-H2C4-C15

    The Allen Bradley 140G-H2C4-C15 is engineered with a four-pole configuration and an interrupting capacity of 25 kA. It supports a current range of 15 Amps and features a rated insulation voltage of 10

    Available
    Call
  • 140G-H3I3-D16 from the 140G MCB series.
    Allen Bradley

    140G-H3I3-D16

    Operating with a current capacity of 160 A, the 140G-H3I3-D16 ensures effective circuit protection. It has a rated insulation voltage of 1000 V and can withstand impulse voltages up to 8 kV. The unit

    Available
    Call
  • 140G-HC6F3-C80 from the 140G MCB series.
    Allen Bradley

    140G-HC6F3-C80

    This model operates with a current range of up to 80 Amps and has a rated insulation voltage of 1000 V. Its impulse withstand voltage is rated at 8 kV. Built for durability, the unit weighs approximat

    Available
    Call
  • 140G-JC6H3-D25 from the 140G MCB series.
    Allen Bradley

    140G-JC6H3-D25

    This molded case circuit breaker features a JC frame and supports a maximum current range of 250 A. It is rated for insulation voltage up to 1000V and can withstand impulse voltages of 8 kV. The devic

    Available
    Call
  • 140G-K0H3-D30 from the 140G MCB series.
    Allen Bradley

    140G-K0H3-D30

    This circuit breaker is part of the K frame series and supports a rated current of 300 A. It operates safely at a rated insulation voltage of up to 1000 volts and withstands impulse voltages of 8 kV.

    Available
    Call
Showing 491-500 of 1,222 results

About 140G MCB

The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.

The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.