Allen Bradley 140G MCB

The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.

Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Browse 140G MCB

Browse available units in our catalog of 140G MCB.

  • 140G-M5K3-D60 from the 140G MCB series.
    Allen Bradley

    140G-M5K3-D60

    Designed within an M frame, the 140G-M5K3-D60 operates effectively with a current range of 600 A. The rated insulation voltage for this unit is 1000 volts, and it can withstand impulse voltages up to

    Available
    Call
  • 140G-H6F3-D11 from the 140G MCB series.
    Allen Bradley

    140G-H6F3-D11

    This circuit breaker utilizes adjustable thermal and magnetic protection. It can manage currents up to 110 A and has an insulation voltage rating of 1000 V. The impulse withstand voltage is rated at 8

    Available
    Call
  • 140G-I2C3-C60 from the 140G MCB series.
    Allen Bradley

    140G-I2C3-C60

    This circuit breaker utilizes both fixed thermal and fixed magnetic protection types. Capable of handling current inputs up to 60 A, it offers a rated insulation voltage of 800 V. The unit withstands

    Available
    Call
  • 140G-J6C3-C40 from the 140G MCB series.
    Allen Bradley

    140G-J6C3-C40

    This molded case circuit breaker utilizes a J frame, which supports a current range of 40 A. It has fixed thermal and magnetic protection to ensure reliability. The insulation voltage rating is 1000 V

    Available
    Call
  • 140G-M0F3-D80 from the 140G MCB series.
    Allen Bradley

    140G-M0F3-D80

    This molded-case circuit breaker operates with an M frame and can handle up to 800 A of maximum current. It is rated for insulation voltages of up to 1000 volts and impulse withstand voltages of 8 kV.

    Available
    Call
  • 140G-G6C3-C60-KA from the 140G MCB series.
    Allen Bradley

    140G-G6C3-C60-KA

    This 3-pole circuit breaker features a thermal trip rating of 60 A and a magnetic trip current of 600 A. It has a maximum breaking capacity of 65 kA and is rated for a voltage of 690 V AC. The unit mo

    Available
    Call
  • 140G-H0C4-C15 from the 140G MCB series.
    Allen Bradley

    140G-H0C4-C15

    The 140G-H0C4-C15 belongs to the molded case circuit breaker series and is equipped with four poles. It operates within a current range of 15 amps and is backed by fixed thermal and magnetic protectio

    Available
    Call
  • 140G-H0C4-C35 from the 140G MCB series.
    Allen Bradley

    140G-H0C4-C35

    Designed as part of the 140G series, the 140G-H0C4-C35 model features a frame size categorized under H. This circuit breaker includes four poles and accommodates a current range of up to 35 A. It offe

    Available
    Call
  • 140G-H0F3-D16 from the 140G MCB series.
    Allen Bradley

    140G-H0F3-D16

    The 140G-H0F3-D16 circuit breaker operates with an adjustable thermal and magnetic protection mechanism. It has been rated to manage currents up to 160 A. With insulation voltage capabilities reaching

    Available
    Call
  • 140G-H0H3-C25 from the 140G MCB series.
    Allen Bradley

    140G-H0H3-C25

    This molded case circuit breaker features a robust frame size H and supports a maximum current capacity of 125 amps. It utilizes electronic LSI protection and maintains a rated insulation voltage of 1

    Available
    Call
Showing 581-590 of 1,222 results

About 140G MCB

The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.

The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.