140G-JTC3-C30
With a rated insulation voltage of 1000 volts and an impulse withstand voltage of up to 8 kV, this circuit breaker provides robust protection. The device is engineered for a mechanical lifespan of 240
The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.
Browse available units in our catalog of 140G MCB.
With a rated insulation voltage of 1000 volts and an impulse withstand voltage of up to 8 kV, this circuit breaker provides robust protection. The device is engineered for a mechanical lifespan of 240
This circuit breaker supports a current range of 70 A and utilizes a JC frame type. It can handle an insulation voltage of 1000 V and withstand impulse voltages up to 8 kV. The item weighs 5.51 pounds
This molded-case circuit breaker is engineered with 4 poles and supports 300 A of rated current. The breaker's rated insulation voltage reaches 1000V, and it also withstands impulse surges of up to 8
This device utilizes a K frame and is equipped with electronic LSIG protection technology. Its rated current is 300 A and its maximum current is 400 A, making it suitable for use in demanding environm
This circuit breaker device offers adjustable thermal and magnetic protection technology, ensuring adaptability to various conditions. It has four poles and operates with 300 A of rated current and 40
Operating with a frame designation of M, this circuit breaker supports a current range of up to 630 Amps. It is rated for an insulation voltage of 1000 volts and can withstand impulse voltages of 8 kV
Designed with an HC frame, the 140G-HTF3-D11 operates within a current range of 110 A. This unit offers a rated insulation voltage of 1000V and withstands impulse voltages of up to 8 kV. Weighing 2.65
This molded case circuit breaker manages a current range of 150 A and maintains an insulation voltage rating of 1000 V. It can withstand impulse voltages up to 8 kV. Weighing 5.51 lbs, it is engineere
Operating within a 250 amp range, this four-pole circuit breaker comes equipped with adjustable thermal and magnetic protection features. It handles insulation voltage ratings up to 1000 V and can wit
This circuit breaker exhibits an H frame size and accommodates 125 Amps standard. With four poles available, it operates effectively at a current range of 30 Amps. The 140G-H0C4-C30 is designed with a
The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.
The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.