Free UPS Ground on All Parcel Orders!
+1 (919) 205-4392
140G MCB

Allen Bradley 140G MCB

The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.

Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Browse 140G MCB

Browse available units in our catalog of 140G MCB.

  • 140G-H6C4-C25 from the 140G MCB series.
    Allen Bradley

    140G-H6C4-C25

    This circuit breaker features a robust H frame configuration and operates with four poles. It supports a current range of 25 A and maintains a rated insulation voltage of 1000 V, along with an impulse

    Available
    Call
  • 140G-H6H4-D10 from the 140G MCB series.
    Allen Bradley

    140G-H6H4-D10

    This circuit breaker operates within a 100 A current range and has a four-pole configuration. It provides a rated insulation voltage of 1000 volts and is designed to withstand impulse voltages of 8 kV

    Available
    Call
  • 140G-H6X4 from the 140G MCB series.
    Allen Bradley

    140G-H6X4

    This molded case circuit breaker operates at rated insulation voltages of 1000 V and withstands impulse voltages of 8 kV. It is structured with a frame size H and weighs 3.53 pounds. The device also b

    Available
    Call
  • 140G-I3C4-D22 from the 140G MCB series.
    Allen Bradley

    140G-I3C4-D22

    This model features four poles and includes fixed thermal and magnetic protection with distinct trip settings. Capable of handling a thermal trip at 220 A and a magnetic trip at 2200 A, its rated insu

    Available
    Call
  • 140G-J2H4-D10 from the 140G MCB series.
    Allen Bradley

    140G-J2H4-D10

    This molded case circuit breaker is designed with four poles and features an interrupting rating of 25 kA. It accommodates 100 A of rated current and 250 A of maximum current and is rated for insulati

    Available
    Call
  • 140G-J2H4-D15 from the 140G MCB series.
    Allen Bradley

    140G-J2H4-D15

    This circuit breaker operates with a rated insulation voltage of 1000 V and is designed to handle an interrupting rating of 25 kA. Its electronic LSI protection technology facilitates enhanced fault d

    Available
    Call
  • 140G-J3C3-C70 from the 140G MCB series.
    Allen Bradley

    140G-J3C3-C70

    This breaker model features a J-frame construction and fixed thermal and magnetic protection mechanisms. Its rated current is 70 A, and it operates efficiently at a rated insulation voltage of 1000 V.

    From $2,085
    Available
  • 140G-J3C4-C25 from the 140G MCB series.
    Allen Bradley

    140G-J3C4-C25

    This circuit breaker offers four poles and is designed with fixed thermal and magnetic protection technology. It supports a rated current of 25 Amps and has a rated insulation voltage of 1000V. The br

    Available
    Call
  • 140G-J6F4-D15 from the 140G MCB series.
    Allen Bradley

    140G-J6F4-D15

    This model features four poles and can operate effectively within a current range of 150 A. It provides a significant interrupting rating of 65 kA, ensuring comprehensive protection for your systems.

    Available
    Call
  • 140G-JC6H3-C40 from the 140G MCB series.
    Allen Bradley

    140G-JC6H3-C40

    This model includes a JC frame type and supports a current range of 40 Amps. With a rated insulation voltage of 1000 volts and withstand voltage up to 8 kV, it is capable of handling various types of

    Available
    Call
Showing 621-630 of 1,222 results

About 140G MCB

The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.

The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.