Free UPS Ground on All Parcel Orders!
+1 (919) 205-4392
140G MCB

Allen Bradley 140G MCB

The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.

Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Browse 140G MCB

Browse available units in our catalog of 140G MCB.

  • 140G-JC6I3-D15 from the 140G MCB series.
    Allen Bradley

    140G-JC6I3-D15

    This circuit breaker features a JC frame and provides protection via an electronic LSIG mechanism. Designed to manage a current range up to 150 Amps, it operates safely at a rated insulation voltage o

    Available
    Call
  • 140G-JTC3-C32 from the 140G MCB series.
    Allen Bradley

    140G-JTC3-C32

    This circuit breaker, part of the 140G series, features a JC frame and supports a current range of 32 A. It can handle rated insulation voltages of 1000 volts and withstand impulse voltages of 8 kV. T

    Available
    Call
  • 140G-KTH4-D40 from the 140G MCB series.
    Allen Bradley

    140G-KTH4-D40

    This four-pole circuit breaker is rated for a maximum current of 400 A and operates at a rated insulation voltage of 1000 V. It withstands impulse voltages of up to 8 kV and weighs 9.15 pounds. It has

    Available
    Call
  • 140G-M0H4-D80 from the 140G MCB series.
    Allen Bradley

    140G-M0H4-D80

    This component features four poles and operates efficiently within a current range of 800 A. The unit is rated for an insulation voltage of 1000 volts and can handle impulse withstands of up to 8 kV.

    Available
    Call
  • 140G-M5X4 from the 140G MCB series.
    Allen Bradley

    140G-M5X4

    This 4-pole circuit breaker is designed specifically for frame-only current ranges and can withstand high insulation voltages of up to 1000 V. The rated impulse withstand voltage is 8 kV, making it ca

    Available
    Call
  • 140G-N0I3-E12-Z1 from the 140G MCB series.
    Allen Bradley

    140G-N0I3-E12-Z1

    Operating at a rated insulation voltage of 1000 volts, this circuit breaker supports a current range of 1200 A. It also withstands impulse voltages up to 8 kV, boasting a weight of 21.39 lbs. Designed

    Available
    Call
  • 140G-N5H4-E12-Z1 from the 140G MCB series.
    Allen Bradley

    140G-N5H4-E12-Z1

    This unit contains four poles and operates within a current range up to 1200 A. It is built with a rated insulation voltage of 1000 V and holds an impulse withstand voltage rating of 8 kV, ensuring it

    Available
    Call
  • 140G-R12I4-E30 from the 140G MCB series.
    Allen Bradley

    140G-R12I4-E30

    Operating within a current range of 2500 to 3000 Amps, this breaker utilizes electronic LSIG protection to maintain safety and reliability. It supports up to 1000 volts of insulation and can withstand

    Available
    Call
  • 140G-JTF3-D20 from the 140G MCB series.
    Allen Bradley

    140G-JTF3-D20

    This molded case circuit breaker achieves a current range of 200 A, backed by an impressive rated insulation voltage of 1000 volts. It is rated to withstand impulse voltages of up to 8 kV. The breaker

    Available
    Call
  • 140G-K3H3-D30 from the 140G MCB series.
    Allen Bradley

    140G-K3H3-D30

    This circuit breaker operates with 300 A of rated current and is equipped with electronic LSI protection. Designed for high-voltage applications, it has a rated insulation voltage of 1000 Volts and wi

    Available
    Call
Showing 631-640 of 1,222 results

About 140G MCB

The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.

The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.