140G MCB

Allen Bradley 140G MCB

The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.

Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Browse 140G MCB

Browse available units in our catalog of 140G MCB.

  • 140G-I2C4-D11 from the 140G MCB series.
    Allen Bradley

    140G-I2C4-D11

    This circuit breaker has a fixed thermal and fixed magnetic protection mechanism and operates with four poles. Its current handling capability reaches 110 A with a thermal trip setting at the same amp

    Available
    Call
  • 140G-I3C3-C90 from the 140G MCB series.
    Allen Bradley

    140G-I3C3-C90

    This circuit breaker employs fixed thermal and fixed magnetic protection mechanisms. It has a thermal trip set at 90 A and magnetic trip set at 900 A. This model is rated for insulation up to 800 volt

    Available
    Call
  • 140G-J0C3-C30 from the 140G MCB series.
    Allen Bradley

    140G-J0C3-C30

    This model features a 250 Amp rating and operates with a fixed thermal and magnetic protection approach. It supports a current range of 30 A and is designed with a rated insulation voltage of 1000 V,

    Available
    Call
  • 140G-J2F4-D22 from the 140G MCB series.
    Allen Bradley

    140G-J2F4-D22

    This circuit breaker has a maximum interrupting capacity of 25 kA and offers adjustable thermal and magnetic protection options. It can handle 220 Amps of rated current and 250 Amps of maximum current

    Available
    Call
  • 140G-J2H3-D15 from the 140G MCB series.
    Allen Bradley

    140G-J2H3-D15

    This circuit breaker has an interrupting capacity of 25 kA and is built with electronic LSI protection features. It operates effectively at a rated current of 150 A and has a rated insulation voltage

    Available
    Call
  • 140G-J2H4-C60 from the 140G MCB series.
    Allen Bradley

    140G-J2H4-C60

    This breaker model features a J frame design and operates with four poles. It offers electronic LSI protection, a rated current of 60 A, and a maximum current of 250 A. The circuit breaker is rated fo

    Available
    Call
  • 140G-J3I4-D10 from the 140G MCB series.
    Allen Bradley

    140G-J3I4-D10

    This circuit breaker is configured with four poles and utilizes electronic LSIG protection. It operates within a current range of up to 100 Amps, suitable for various applications. The module supports

    Available
    Call
  • 140G-J6C3-C63 from the 140G MCB series.
    Allen Bradley

    140G-J6C3-C63

    This molded case circuit breaker utilizes fixed thermal and fixed magnetic protection types, handling a current range of up to 63 Amps. It is rated for insulation up to 1000 volts and withstands impul

    Available
    Call
  • 140G-J6I3-C40 from the 140G MCB series.
    Allen Bradley

    140G-J6I3-C40

    This device features a J-frame and maintains a current range of 40 A. The rated insulation voltage is 1000 V, while it can withstand impulse voltages of up to 8 kV. Weighing 5.51 pounds, it includes e

    Available
    Call
  • 140G-JC6C3-C60 from the 140G MCB series.
    Allen Bradley

    140G-JC6C3-C60

    Part number 140G-JC6C3-C60 features a JC frame and can handle a current range of up to 60 A. It is rated for an insulation voltage of 1000 V and withstands impulse voltages of 8 kV, ensuring reliable

    Available
    Call
Showing 671-680 of 1,222 results

About 140G MCB

The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.

The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.