Free UPS Ground on All Orders!
+1 (919) 205-4392
140G MCB

Allen Bradley 140G MCB

The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.

Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Browse 140G MCB

Browse available units in our catalog of 140G MCB.

140G-I2C4-D11

This circuit breaker has a fixed thermal and fixed magnetic protection mechanism and operates with four poles. Its current handling capability reaches 110 A with a thermal trip setting at the same amp

Call
5.0

140G-I3C4-D15

This circuit breaker features four poles and operates with fixed thermal and magnetic trip types. It can accommodate a current range of up to 150 A and has an insulation voltage rating set at 800 V. T

Call
4.9

140G-J0C3-C40

This circuit breaker has a J frame design and offers an interrupting capacity of 100 kA. It supports a current range of 40 Amps while operating safely at a rated insulation voltage of 1000 volts. This

Call
4.9

140G-J0C4-C25

This circuit breaker includes four poles and operates within a current range of 25 A. It has fixed thermal and fixed magnetic protection types, ensuring reliable operation in various conditions. The r

Call
4.7

140G-J0F3-D16

This circuit breaker can accommodate a current range up to 160 A and is built with adjustable thermal and magnetic protection for enhanced fault management. It supports a rated insulation voltage of 1

Call
4.7

140G-J0F4-D17

Configured for a current range of 170 A, the 140G-J0F4-D17 circuit breaker operates at a rated insulation voltage of 1000 V and can withstand impulse voltages of 8 kV. Weighing 7.72 pounds, this circu

Call
5.0

140G-J0H3-C40

This circuit breaker utilizes electronic LSI technology for advanced protection and operates with a rated current of 40 A. It withstands rated insulation voltages up to 1000V, and its maximum impulse

Call
4.7

140G-J0H3-D10

This circuit breaker is built within a J frame and operates with electronic LSI protection options. It supports a rated current of up to 100 A and is rated for insulation voltages of 1000 V. This circ

Call
4.3

140G-J2C3-C63

The 140G-J2C3-C63 features fixed thermal and fixed magnetic protection options, a current rating of 63 A, and a maximum rated current of 250 A. It operates at a rated insulation voltage of 1000 V and

Call
5.0

140G-J2F4-D22

This circuit breaker has a maximum interrupting capacity of 25 kA and offers adjustable thermal and magnetic protection options. It can handle 220 Amps of rated current and 250 Amps of maximum current

Call
4.6
Showing 651-660 of 1,219 results

About 140G MCB

The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.

The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.