140G-J0C3-C40
This circuit breaker has a J frame design and offers an interrupting capacity of 100 kA. It supports a current range of 40 Amps while operating safely at a rated insulation voltage of 1000 volts. This
The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.
Browse available units in our catalog of 140G MCB.
This circuit breaker has a J frame design and offers an interrupting capacity of 100 kA. It supports a current range of 40 Amps while operating safely at a rated insulation voltage of 1000 volts. This
This circuit breaker operates effectively within a current range of 110 A. It offers adjustable thermal and magnetic protection types, with a rated insulation voltage of 1000 V. The impulse withstand
This circuit breaker includes fixed thermal and fixed magnetic protection technology and operates with a rated current of 70 Amps and up to 250 Amps of maximum current. It supports a rated insulation
Operating as a four-pole circuit breaker, the 140G-J6F4-D22 accommodates a current range of up to 220 A. It integrates adjustable thermal and magnetic protection, making it adaptable to various applic
This breaker is equipped with a four-pole design and is built in a J-frame structure. It has an insulation voltage rating of 1000 Volts and is capable of withstanding impulse voltages of up to 8 kV. W
This 4-pole circuit breaker is designed to operate with a rated current of 300 A. It features electronic LSIG protection and is rated for an insulation voltage of 1000 volts. It can handle impulse wit
This circuit breaker operates with a rated insulation voltage of 1000 Volts and withstands impulse voltages of up to 8 kV. The unit has a weight of 7.17 pounds and features a mechanical life rating of
This molded-case circuit breaker is rated for 400 Amps and operates with a maximum rated insulation voltage of 1000 volts. It features a K-frame design tailored for effective current management. The d
This molded-case circuit breaker features a K frame and employs electronic LSIG protection. It operates efficiently with 300 A of rated current and has a rated insulation voltage of 1000 volts, ensuri
This unit operates at a maximum current range of 800 A and comes with an interrupting rating governed by the trip unit. Capable of functioning under an insulation voltage of 1000 Volts, it withstands
The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.
The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.