Free UPS Ground on All Parcel Orders!
+1 (919) 205-4392
140G MCB

Allen Bradley 140G MCB

The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.

Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Browse 140G MCB

Browse available units in our catalog of 140G MCB.

  • 140G-I3C4-D10 from the 140G MCB series.
    Allen Bradley

    140G-I3C4-D10

    This unit operates with a maximum current range of 100 A, featuring a fixed thermal trip setting at this point and a fixed magnetic trip rating of 1000 A. It provides a rated insulation voltage of 800

    Available
    Call
  • 140G-J0C3-C25 from the 140G MCB series.
    Allen Bradley

    140G-J0C3-C25

    This model features a J-frame design and operates within a current range of 25 A. It possesses a rated insulation voltage of 1000 V, along with an impulse withstand voltage rating of 8 kV. Weighing 5.

    Available
    Call
  • 140G-J0C4-C25 from the 140G MCB series.
    Allen Bradley

    140G-J0C4-C25

    This circuit breaker includes four poles and operates within a current range of 25 A. It has fixed thermal and fixed magnetic protection types, ensuring reliable operation in various conditions. The r

    Available
    Call
  • 140G-J0F4-C90 from the 140G MCB series.
    Allen Bradley

    140G-J0F4-C90

    This circuit breaker features an adjustable thermal and magnetic protection type, maximizing its adaptability for various electrical environments. With four poles and a current range of 90 A, it is su

    Available
    Call
  • 140G-J0H3-C60 from the 140G MCB series.
    Allen Bradley

    140G-J0H3-C60

    This circuit breaker operates with a rated current of up to 60 Amps. It can withstand rated insulation voltages up to 1000 Volts and has an impulse withstand voltage rating of 8 kV. The frame size of

    Available
    Call
  • 140G-J0H3-D10 from the 140G MCB series.
    Allen Bradley

    140G-J0H3-D10

    This circuit breaker is built within a J frame and operates with electronic LSI protection options. It supports a rated current of up to 100 A and is rated for insulation voltages of 1000 V. This circ

    Available
    Call
  • 140G-J2C3-C63 from the 140G MCB series.
    Allen Bradley

    140G-J2C3-C63

    The 140G-J2C3-C63 features fixed thermal and fixed magnetic protection options, a current rating of 63 A, and a maximum rated current of 250 A. It operates at a rated insulation voltage of 1000 V and

    Available
    Call
  • 140G-J3H4-D15 from the 140G MCB series.
    Allen Bradley

    140G-J3H4-D15

    Designed for reliable circuit protection, the 140G-J3H4-D15 operates at a maximum rated insulation voltage of 1000 volts and supports a current range up to 150 Amps. It includes an interrupting capaci

    Available
    Call
  • 140G-J6H4-D25 from the 140G MCB series.
    Allen Bradley

    140G-J6H4-D25

    Specializing in electronic LSI protection, this model includes four poles and operates within a current range of 25 A. It is rated to handle insulation voltages of 1000 volts and impulse withstand vol

    Available
    Call
  • 140G-JTI4-D10 from the 140G MCB series.
    Allen Bradley

    140G-JTI4-D10

    This breaker operates with a maximum current capacity of 250 Amps and incorporates a trip unit for effective fault interruption. It supports an insulation voltage rating of 1000 volts and can withstan

    Available
    Call
Showing 701-710 of 1,222 results

About 140G MCB

The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.

The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.