140G MCB

Allen Bradley 140G MCB

The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.

Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Browse 140G MCB

Browse available units in our catalog of 140G MCB.

  • 140G-H2I4-D12 from the 140G MCB series.
    Allen Bradley

    140G-H2I4-D12

    This circuit breaker includes four poles and is rated for a current range up to 120 Amps. It operates at a rated insulation voltage of 1000 V and is constructed to withstand impulse voltages of 8 kV.

    Available
    Call
  • 140G-H3C4-C40 from the 140G MCB series.
    Allen Bradley

    140G-H3C4-C40

    This four-pole circuit breaker supports a current range of 40 Amps and includes fixed thermal and magnetic protection types. It operates effectively under rated insulation voltages up to 1000 Volts an

    Available
    Call
  • 140G-H3F4-C90 from the 140G MCB series.
    Allen Bradley

    140G-H3F4-C90

    Engineered for efficiency, the 140G-H3F4-C90 circuit breaker operates within a current range of 90 A. It employs adjustable thermal and magnetic protection mechanisms for customized operation. This de

    Available
    Call
  • 140G-H3F4-D11 from the 140G MCB series.
    Allen Bradley

    140G-H3F4-D11

    The 140G-H3F4-D11 circuit breaker has four poles and is capable of handling a maximum current of 110 A within its classification. Rated insulation voltage is 1000 V, and it withstands impulse voltages

    Available
    Call
  • 140G-H3H3-C60 from the 140G MCB series.
    Allen Bradley

    140G-H3H3-C60

    This model features a current range of 60 A and operates effectively at a rated insulation voltage of 1000 V. It can withstand impulse voltages of up to 8 kV. This unit, weighing 2.65 pounds, is desig

    Available
    Call
  • 140G-H3H3-D10 from the 140G MCB series.
    Allen Bradley

    140G-H3H3-D10

    This molded case circuit breaker is rated for a maximum insulation voltage of 1000 V and can withstand impulse voltages of 8 kV. It is housed within an H frame type. Weighing 2.65 pounds, it supports

    Available
    Call
  • 140G-HC0C3-C63 from the 140G MCB series.
    Allen Bradley

    140G-HC0C3-C63

    This breaker, classified within the HC frame size, supports a current range of 63 Amps. It is equipped with fixed thermal and magnetic protection, suitable for a wide range of applications. The rated

    Available
    Call
  • 140G-HC0I3-C60 from the 140G MCB series.
    Allen Bradley

    140G-HC0I3-C60

    This circuit breaker has an HC frame type and supports a current range of 60A. With a rated insulation voltage of 1000V and a withstand voltage of 8 kV, it ensures robust protection under diverse cond

    Available
    Call
  • 140G-HC0I3-D12 from the 140G MCB series.
    Allen Bradley

    140G-HC0I3-D12

    This molded case circuit breaker supports a current range of 120 A and is designed with Electronic LSIG protection. It has a rated insulation voltage of 1000 V and is capable of handling impulse withs

    Available
    Call
  • 140G-I3C4-C80 from the 140G MCB series.
    Allen Bradley

    140G-I3C4-C80

    Designed under the I frame, the 140G-I3C4-C80 model accommodates currents of 80 A and supports a rated insulation voltage of 800 V. It can withstand impulse voltages of 8 kV, making it suitable for de

    Available
    Call
Showing 721-730 of 1,222 results

About 140G MCB

The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.

The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.