The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.

Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Browse 140G MCB

Browse available units in our catalog of 140G MCB.

  • 140G-J2I3-D25 from the 140G MCB series.
    Allen Bradley

    140G-J2I3-D25

    This circuit breaker features a J frame design and operates within a current capacity of 250 A. It supports a rated insulation voltage of 1000 V and has the capability to withstand impulse voltages of

    Available
    Call
  • 140G-H2C3-C32 from the 140G MCB series.
    Allen Bradley

    140G-H2C3-C32

    The 140G-H2C3-C32 series represents a molded case circuit breaker equipped with fixed thermal and magnetic protection type. It can accommodate a current range of 32 Amps and is rated for an insulation

    Available
    Call
  • 140G-H15I3-C60 from the 140G MCB series.
    Allen Bradley

    140G-H15I3-C60

    This circuit breaker is equipped with an electronic LSIG protection system and provides a current range rated at 60 amps. The rated insulation voltage is set at 1000 volts, and it can endure impulse v

    Available
    Call
  • 140G-H2F4-D12 from the 140G MCB series.
    Allen Bradley

    140G-H2F4-D12

    This circuit breaker offers an H frame construction with four poles and supports an adjustable thermal and magnetic protection type. Its current operating range is set at 120 amps, with rated insulati

    Available
    Call
  • 140G-H2I3-C60 from the 140G MCB series.
    Allen Bradley

    140G-H2I3-C60

    This model is crafted for 60 A current range applications. It has a rated insulation voltage of 1000 V and withstands impulse voltages up to 8 kV. A weight of 2.65 lbs makes it suitable for a variety

    Available
    Call
  • 140G-H3C3-C20 from the 140G MCB series.
    Allen Bradley

    140G-H3C3-C20

    The 140G-H3C3-C20 circuit breaker is designed to support an input current range of 20 amps. It operates at a rated insulation voltage of 1000 V and withstands impulse voltages of up to 8 kV. This mode

    Available
    Call
  • 140G-H3C4-C50 from the 140G MCB series.
    Allen Bradley

    140G-H3C4-C50

    This model features four poles and includes fixed thermal and magnetic protection mechanisms. It can handle currents up to 50 A, with a rated insulation voltage of 1000 volts and an impulse withstand

    Available
    Call
  • 140G-H3H4-D10 from the 140G MCB series.
    Allen Bradley

    140G-H3H4-D10

    The 140G-H3H4-D10 is a four-pole circuit breaker that features an electronic LSI protection mechanism, suitable for managing a range of 100 A. This unit supports rated insulation up to 1000 V and can

    Available
    Call
  • 140G-H3I4-D16 from the 140G MCB series.
    Allen Bradley

    140G-H3I4-D16

    With a frame size of H, this circuit breaker supports a current range of up to 160 A. It operates efficiently with a rated insulation voltage of 1000 volts and withstands impulse voltages of 8 kV. Wei

    Available
    Call
  • 140G-H6I4-D10 from the 140G MCB series.
    Allen Bradley

    140G-H6I4-D10

    This model is structured with four poles and operates within a current range of 100 Amps. It is equipped with electronic LSIG protection and can handle an insulation voltage of 1000 V. With an impulse

    Available
    Call
Showing 751-760 of 1,222 results

About 140G MCB

The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.

The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.