140G MCB

Allen Bradley 140G MCB

The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.

Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Browse 140G MCB

Browse available units in our catalog of 140G MCB.

  • 140G-J3I3-C40 from the 140G MCB series.
    Allen Bradley

    140G-J3I3-C40

    Designed as a J frame circuit breaker, the 140G-J3I3-C40 supports a current range of 40 A. It withstands rated insulation voltages of 1000 V and impulse withstand voltages of up to 8 kV. Weighing 5.51

    Available
    Call
  • 140G-J6C3-C35 from the 140G MCB series.
    Allen Bradley

    140G-J6C3-C35

    This unit, part of the 140G series, is classified with a J frame and supports a current range of 35 A. It offers ratings of 1000 V for its insulation voltage, and can withstand impulse voltages up to

    Available
    Call
  • 140G-J6I3-D15 from the 140G MCB series.
    Allen Bradley

    140G-J6I3-D15

    Designed for diverse applications, this breaker supports a current range up to 150 A. It is rated for 1000 volts of insulation and can withstand impulse voltages up to 8 kV. Weighing 5.51 pounds, it o

    Available
    Call
  • 140G-J6I4-D15 from the 140G MCB series.
    Allen Bradley

    140G-J6I4-D15

    This circuit breaker includes four poles and operates with electronic LSIG protection. It has a current range of up to 150 Amps and can function safely at a rated insulation voltage of 1000V. The devi

    Available
    Call
  • 140G-JTC3-C63 from the 140G MCB series.
    Allen Bradley

    140G-JTC3-C63

    This circuit breaker operates within a current range of 63 Amps and possesses a rated insulation voltage of 1000 V. Additionally, it can withstand impulse voltages of up to 8 kV. Weighing 5.51 pounds,

    Available
    Call
  • 140G-JTF3-C80 from the 140G MCB series.
    Allen Bradley

    140G-JTF3-C80

    Designed with a J frame, the 140G-JTF3-C80 circuit breaker is adaptable for a current range of 80 Amps. It supports insulation voltages rated up to 1000 Volts and withstands impulse voltages of 8 kV.

    Available
    Call
  • 140G-JTF4-D10 from the 140G MCB series.
    Allen Bradley

    140G-JTF4-D10

    This molded case circuit breaker offers a configuration with four poles. It operates within a current range of up to 100 Amps. The unit withstands rated impulse voltages of 8 kV, providing robust prot

    Available
    Call
  • 140G-JTF4-D22 from the 140G MCB series.
    Allen Bradley

    140G-JTF4-D22

    This circuit breaker utilizes a four-pole configuration and maintains a current range of 220 Amps. It has an insulation voltage rating of 1000 volts and can withstand impulse voltages of 8 kV. The uni

    Available
    Call
  • 140G-K0K3-D40 from the 140G MCB series.
    Allen Bradley

    140G-K0K3-D40

    This circuit breaker operates with a design that supports a current capacity of 400 A and incorporates an insulation voltage rating of 1000 volts. Its rated impulse withstand voltage is 8 kV. Weighing

    Available
    Call
  • 140G-K3X4 from the 140G MCB series.
    Allen Bradley

    140G-K3X4

    This molded-case circuit breaker has four poles and supports a rated insulation voltage of 1000 volts. The impulse withstand voltage is rated at 8 kV. At 9.15 pounds, this breaker has a mechanical lif

    Available
    Call
Showing 771-780 of 1,222 results

About 140G MCB

The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.

The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.