140G-H6C4-C50
With a current range of 50 A, this circuit breaker offers high performance and efficiency. It is designed to withstand rated insulation voltages up to 1000 V and can handle impulse voltages reaching 8
The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.
Browse available units in our catalog of 140G MCB.
With a current range of 50 A, this circuit breaker offers high performance and efficiency. It is designed to withstand rated insulation voltages up to 1000 V and can handle impulse voltages reaching 8
With a frame designation of H, the 140G-H6H4-D12 supports an electrical life rated at 120 operations per hour and a mechanical life of up to 240 operations per hour. This circuit breaker can handle cu
This model handles a maximum current of 110 A and has specific trip settings for thermal protection at 110 A and magnetic protection at 1100 A. It operates efficiently at a rated insulation voltage of
This molded case circuit breaker operates on a frame size of I and supports a current range of 120 Amps. With a rated insulation voltage of 800 Volts and an impulse withstand voltage of 8 kV, this dev
This molded case circuit breaker features a four-pole design and utilizes fixed thermal and fixed magnetic protection types. It supports a thermal trip setting of 160 A and handles magnetic trips up t
This model is equipped with four poles and offers fixed thermal and magnetic trip mechanisms for reliable operation. It operates within a specified current range of 63 A and supports a rated insulatio
This circuit breaker operates within a current range of 35 A, offering reliable electrical insulation with a rating of 1000 volts. The breaker withstands impulse voltages that reach 8 kV. Weighing 5.5
This device integrates four poles and is designed for a current range of 30 A. It supports a rated insulation voltage of 1000 V and an impulse withstand voltage of 8 kV. Weighing 7.72 lb, the 140G-J0C
This molded case circuit breaker operates within a current range of 90 A, featuring a rated insulation voltage capacity of 1000 volts. It is designed to withstand impulse voltages up to 8 kV. The unit
This circuit breaker, belonging to the J frame size, features adjustable thermal and magnetic protection mechanisms. It operates effectively within a current range of 220 A and has a rated insulation
The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.
The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.